Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 4, 2018, 10:19 AM
  • 15 1086_H 0425_04052018_034319.mp4

Date
05/04/2018
W/O
696294
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00614
PipeID
P12846
Time
3:19 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5586
Sewer Name
15 MERCED TRUNK, SECTION 1
City
SOUTH EL MONTE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
28
Purpose
Routine Assessment
Project
WO_696294_TV15099_APR2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
15 1086
Downstream MH
H 0425
Dir. of Survey
Downstream
Length Surveyed
119 ft.
Total Length
119 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
412D
O&M Rating
52
Overall Index
2
Overall Quick
Overall Rating
55
Pipe schematic from manhole 15 1086 to H 0425
MH: 15 1086MH: H 0425downstream0 ft. MGO - General Observation - ACTIVE CONNECTION 9 O'CLOCK0 ft. MGO - General Observation - COCKROACHES IN MANHOLE0 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 02 to 10 o'clock, , within 8 inches of joint: YES, Start0 ft. AMH - Upstream Manhole, Survey Begins - 15 10860 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 70 %of cross sectional area17 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"68.9 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"71.7 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 4"112.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"113.5 ft. CM - Crack Multiple, from 12 to 02 o'clock, within 8 inches of joint: YES119 ft. AMH - Downstream Manhole, Survey Ends - H 0425119 ft. MGO - General Observation - ACTIVE CONNECTON 9 O'CLOCK119 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 02 to 10 o'clock, , within 8 inches of joint: YES, Finish119 ft. MGO - General Observation - COCKROACHES IN MANHOLE

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 02 to 10 o'clock,  , within 8 inches of joint: YES, Start

    0 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 02 to 10 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 12 to 02 o'clock, within 8 inches of joint: YES

    113.5 ft. - Crack Multiple, from 12 to 02 o'clock, within 8 inches of joint: YES

Observations (15)

DistanceCodeObservation
119AMHH 0425
119MGOACTIVE CONNECTON 9 O'CLOCK
0MGOACTIVE CONNECTION 9 O'CLOCK
119DAGS
0MGOCOCKROACHES IN MANHOLE
0DAGS
0AMH15 1086
119MGOCOCKROACHES IN MANHOLE
113.5CM
71.7TFA
0MWL
0MWM
112.6TFC
68.9TFA
17TFA

Properties (5)

additional_info
SC358550
custom_field_two
3
customer
LACSD
datetime
2018-05-04T03:19:50-07:00
is_lateral_inspection
false