Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 17, 2019, 05:06 AM
  • 05 0760_05 0759 _04162019_222901.mp4

Date
04/16/2019
W/O
761391
Weather
Dry
Operator/Surveyor
E.RUIZ
Sewer ID
Z00484
PipeID
P05987
Time
10:06 PM
Certificate
U-715-07000753
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6520
Sewer Name
05 MANCHESTER-VERMONT RELIEF TRUNK
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
09
Purpose
Routine Assessment
Project
RFIR_WO_761391_TV05315_APR2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
05 0760
Downstream MH
05 0759
Dir. of Survey
Downstream
Length Surveyed
423.4 ft.
Total Length
423.4 ft.
Structural Index
4
Structural Quick
4200
Structural Rating
8
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
8
Pipe schematic from manhole 05 0760 to 05 0759
MH: 05 0760MH: 05 0759downstream0 ft. AMH - Upstream Manhole, Survey Begins - 05 07600 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. MWL - Water Level, 35 %of cross sectional area2.9 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES7.9 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start421.2 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish423.4 ft. AMH - Downstream Manhole, Survey Ends - 05 0759

Observation photos (2)

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    2.9 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    7.9 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (7)

DistanceCodeObservation
7.9FM
2.9FM
421.2FM
0AMH05 0760
0MWM
0MWL
423.4AMH05 0759

Properties (4)

custom_field_two
2
customer
LACSD
datetime
2019-04-16T22:06:17-07:00
is_lateral_inspection
false