Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 30, 2019, 05:53 AM
  • 02 0994_02 0993_04292019_231026.mp4

Date
04/29/2019
W/O
761346
Weather
Dry
Operator/Surveyor
E.RUIZ
Sewer ID
Z00279
PipeID
P03566
Time
10:53 PM
Certificate
U-715-07000753
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6522
Sewer Name
02 MONTEBELLO TRUNK
City
COMMERCE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
18
Purpose
Routine Assessment
Project
RFIR_WO_761346_TV02334_APR2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
02 0994
Downstream MH
02 0993
Dir. of Survey
Downstream
Length Surveyed
173.8 ft.
Total Length
173.8 ft.
Structural Index
4
Structural Quick
4E31
Structural Rating
127
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
127
Pipe schematic from manhole 02 0994 to 02 0993
MH: 02 0994MH: 02 0993downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 099411.2 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES12.9 ft. FM - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES16.2 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start109.1 ft. RPZ - Repair Other, within 8 inches of joint: YES - TOP OF PIPE REPAIRED109.1 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish116.3 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start170 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: YES, 8"171.9 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish173.8 ft. AMH - Downstream Manhole, Survey Ends - 02 0993

Observation photos (5)

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    11.2 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    12.9 ft. - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    16.2 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Repair Other, within 8 inches of joint: YES - TOP OF PIPE REPAIRED

    109.1 ft. - Repair Other, within 8 inches of joint: YES - TOP OF PIPE REPAIRED

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    116.3 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (12)

DistanceCodeObservation
109.1RPZTOP OF PIPE REPAIRED
171.9FM
0MWL
173.8AMH02 0993
12.9FM
11.2CM
170TB
16.2FM
109.1FM
0MWM
116.3FM
0AMH02 0994

Properties (4)

custom_field_two
2
customer
LACSD
datetime
2019-04-29T22:53:33-07:00
is_lateral_inspection
false