Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 11, 2019, 05:10 AM
  • F 0162_F 0161 _04102019_222741.mp4

Date
04/10/2019
W/O
761821
Weather
Dry
Operator/Surveyor
J. BUENROSTO
Sewer ID
Z00044
PipeID
P10297
Time
10:10 PM
Certificate
U-715-07000770
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K5852
Sewer Name
F JOINT OUTFALL F - UNIT 7B
City
NORWALK
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
37A
Purpose
Routine Assessment
Project
RFIR_WO_761821_TV18071_APR2019
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
48 in.
Width
48 in.
Upstream MH
F 0162
Downstream MH
F 0161
Dir. of Survey
Downstream
Length Surveyed
458.1 ft.
Total Length
458.1 ft.
Structural Index
2
Structural Quick
2100
Structural Rating
2
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
4
Pipe schematic from manhole F 0162 to F 0161
MH: F 0162MH: F 0161downstream0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - F 01620 ft. MWL - Water Level, 35 %of cross sectional area9.4 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start9.4 ft. DAZ - Deposits Attached Other, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start - MAG COATING456.7 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish456.7 ft. DAZ - Deposits Attached Other, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Finish458.1 ft. AMH - Downstream Manhole, Survey Ends - F 0161

Observation photos (1)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    9.4 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
456.7SSS
9.4SSS
9.4DAZMAG COATING
458.1AMHF 0161
456.7DAZ
0MWM
0AMHF 0162
0MWL

Properties (6)

additional_info
SC366093
custom_field_two
3
customer
LACSD
datetime
2019-04-10T22:10:44-07:00
documentation
PROPIPE
is_lateral_inspection
false