Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 21, 2018, 09:15 AM
  • 08 0198_08 0197 _21122018_011621.mp4

Date
12/21/2018
W/O
740635
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00010
PipeID
P00258
Time
1:15 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6254
Sewer Name
08 GRACE STREET TRUNK, SECTS 2&3
City
CARSON
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
11
Purpose
Routine Assessment
Project
RFIR_WO_740635_TV08022_DEC2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
08 0198
Downstream MH
08 0197
Dir. of Survey
Downstream
Length Surveyed
162.3 ft.
Total Length
162.3 ft.
Structural Index
3
Structural Quick
413E
Structural Rating
97
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
97
Pipe schematic from manhole 08 0198 to 08 0197
MH: 08 0198MH: 08 0197downstream0 ft. AMH - Upstream Manhole, Survey Begins - 08 01980 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area2.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start50 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"96 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"144.8 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES156.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"156.8 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish162.3 ft. AMH - Downstream Manhole, Survey Ends - 08 0197

Observation photos (2)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.6 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    144.8 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

Observations (11)

DistanceCodeObservation
144.8FM
50TFC
0AMH08 0198
0MGOCONNECTION AT MH 3 O'CLOCK
96TF
162.3AMH08 0197
156.8TFC
0MWL
0MWM
156.8CM
2.6CM

Properties (6)

additional_info
SC365487
custom_field_two
3
customer
LACSD
datetime
2018-12-21T01:15:55-08:00
documentation
PROPIPE
is_lateral_inspection
false