Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 30, 2019, 05:42 PM
  • 30 0212_30 0226_5302019_105644.mp4

Date
05/30/2019
W/O
0771073
Weather
Dry
Operator/Surveyor
FRANKLIN
Sewer ID
Z00884
PipeID
P17927
Time
10:42 AM
Certificate
U-415-06024039
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7990
Sewer Name
30 VIA CAMPESINA TRUNK
City
PALOS VERDES ESTATES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 30
Page No.
09
Purpose
Capital Improvement Program Assesment
Project
20190529DF_VIA_CAMPESINA_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Upstream MH
30 0226
Downstream MH
30 0212
Dir. of Survey
Upstream
Length Surveyed
123 ft.
Total Length
123 ft.
Structural Index
3
Structural Quick
3121
Structural Rating
5
O&M Index
1
O&M Quick
1100
O&M Rating
1
Overall Index
2
Overall Quick
Overall Rating
6
Pipe schematic from manhole 30 0226 to 30 0212
MH: 30 0226MH: 30 0212upstream0 ft. MGO - General Observation - STOPLOG DOWN @ 12 O'CLOCK0 ft. MGO - General Observation - Grease Throughout The Reach (5%)0 ft. AMH - Upstream Manhole, Survey Ends - 11:15 AM1.3 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YESR, Finish1.3 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish1.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish15.5 ft. MGP - General Photograph15.5 ft. MGP - General Photograph50.6 ft. MGP - General Photograph58.2 ft. MGP - General Photograph58.2 ft. MGP - General Photograph70.5 ft. MGP - General Photograph118.7 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YESR, Start121 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start121 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start123 ft. MWL - Water Level, 0% %of cross sectional area123 ft. AMH - Downstream Manhole, Survey Begins - 10:46 AM123 ft. MWM - Water Mark, 5 %of cross sectional area

Observation photos (10)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YESR, Start

    4.3 ft. - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YESR, Start

  • General Photograph

    52.5 ft. - General Photograph

  • General Photograph

    64.8 ft. - General Photograph

  • General Photograph

    64.8 ft. - General Photograph

  • General Photograph

    72.4 ft. - General Photograph

  • General Photograph

    107.5 ft. - General Photograph

  • General Photograph

    107.5 ft. - General Photograph

  • General Observation - STOPLOG DOWN @ 12 O'CLOCK

    123 ft. - General Observation - STOPLOG DOWN @ 12 O'CLOCK

Observations (18)

DistanceCodeObservation
123MGOSTOPLOG DOWN @ 12 O'CLOCK
0MWL
52.5MGP
0AMH10:46 AM
72.4MGP
0MWM
4.3RFJ
64.8MGP
121.7RFJ
64.8MGP
107.5MGP
121.7SSS
2SSS
123MGOGrease Throughout The Reach (5%)
2CM
123AMH11:15 AM
107.5MGP
121.7CM

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2019-05-30T10:42:13-07:00
documentation
FRANKLIN, BRAR, CASTILLO
is_lateral_inspection
false