Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 29, 2019, 05:12 PM
  • 30 0231_30 0230_5292019_101921.mp4

Date
05/29/2019
W/O
0771073
Weather
Dry
Operator/Surveyor
FRANKLIN
Sewer ID
Z00884
PipeID
P17932
Time
10:12 AM
Certificate
U-415-06024039
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7989
Sewer Name
30 VIA CAMPESINA TRUNK
City
PALOS VERDES ESTATES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 30
Page No.
09
Purpose
Capital Improvement Program Assesment
Project
20190529DF_VIA_CAMPESINA_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Upstream MH
30 0231
Downstream MH
30 0230
Dir. of Survey
Downstream
Length Surveyed
234.6 ft.
Total Length
234.6 ft.
Structural Index
3
Structural Quick
5141
Structural Rating
19
O&M Index
2
O&M Quick
3111
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
23
Pipe schematic from manhole 30 0231 to 30 0230
MH: 30 0231MH: 30 0230downstream0 ft. AMH - Upstream Manhole, Survey Begins - 10:14 AM0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 15 %of cross sectional area2 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YESR, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start3.8 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: YES, 4"5.9 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: YES, 4"23.6 ft. MGP - General Photograph31.5 ft. B - Broken, from 10 to 02 o'clock, within 8 inches of joint: YES31.5 ft. FM - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES68.2 ft. MGP - General Photograph81.2 ft. TBD - Tap Break-In Defective, at 10 o'clock, -, , within 8 inches of joint: YES, 4" - 75% ROOTS/GREASE-LATERAL96 ft. FS - Fracture Spiral, from 06 to 10 o'clock, within 8 inches of joint: YES139.8 ft. TFA - Tap Factory Made Active, at 09 o'clock, -, within 8 inches of joint: YES, 4"150.2 ft. MGP - General Photograph199.9 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: YES, 4" - 70% ROOTS-LATERAL199.9 ft. MWLS - Water Level, Sag in pipe, 10 %of cross sectional area, Start213.4 ft. MGP - General Photograph219.5 ft. MGP - General Photograph220 ft. MWLS - Water Level, Sag in pipe, 10 %of cross sectional area, Finish220.4 ft. TBA - Tap Break-In Active, at 09 o'clock, -, within 8 inches of joint: YES, 4" - 95% GREASE/ROOTS-LATERAL228.5 ft. MGP - General Photograph232.9 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YESR, Finish232.9 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish232.9 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish234.6 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active234.6 ft. AMH - Downstream Manhole, Survey Ends - 10:44 AM234.6 ft. MGO - General Observation - GREASE THROUGHOUT THE REACH (5%)

Observation photos (14)

  • Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YESR, Start

    2 ft. - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YESR, Start

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Photograph

    23.6 ft. - General Photograph

  • Broken, from 10 to 02 o'clock, within 8 inches of joint: YES

    31.5 ft. - Broken, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    31.5 ft. - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

  • General Photograph

    68.2 ft. - General Photograph

  • Tap Break-In Defective, at 10 o'clock, -,  , within 8 inches of joint: YES, 4" - 75% ROOTS/GREASE-LATERAL

    81.2 ft. - Tap Break-In Defective, at 10 o'clock, -, , within 8 inches of joint: YES, 4" - 75% ROOTS/GREASE-LATERAL

  • Fracture Spiral, from 06 to 10 o'clock, within 8 inches of joint: YES

    96 ft. - Fracture Spiral, from 06 to 10 o'clock, within 8 inches of joint: YES

  • General Photograph

    150.2 ft. - General Photograph

  • Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: YES, 4" - 70% ROOTS-LATERAL

    199.9 ft. - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: YES, 4" - 70% ROOTS-LATERAL

  • General Photograph

    213.4 ft. - General Photograph

  • General Photograph

    219.5 ft. - General Photograph

  • Tap Break-In Active, at 09 o'clock, -, within 8 inches of joint: YES, 4" - 95% GREASE/ROOTS-LATERAL

    220.4 ft. - Tap Break-In Active, at 09 o'clock, -, within 8 inches of joint: YES, 4" - 95% GREASE/ROOTS-LATERAL

  • General Photograph

    228.5 ft. - General Photograph

Observations (30)

DistanceCodeObservation
2MGOConn. @ Mh, 9 O' Clock. Active
220.4TBA95% GREASE/ROOTS-LATERAL
31.5B
31.5FM
2CM
199.9TFC70% ROOTS-LATERAL
96FS
234.6MGOConn. @ Mh, 9 O' Clock. Active
68.2MGP
81.2TBD75% ROOTS/GREASE-LATERAL
0AMH10:14 AM
199.9MWLS
234.6AMH10:44 AM
2RFJ
213.4MGP
2SSS
232.9RFJ
150.2MGP
219.5MGP
234.6MGOGREASE THROUGHOUT THE REACH (5%)
3.8TFA
0MWL
0MWM
232.9SSS
23.6MGP
139.8TFA
5.9TFC
220MWLS
228.5MGP
232.9CM

Properties (6)

additional_info
THE ONSCREEN W.O. NUMBER IS WRONG. THE CORRECT W.O. NUMBER IS (0771073)
custom_field_two
3
customer
LACSD
datetime
2019-05-29T10:12:42-07:00
documentation
FRANKLIN, BRAR, CASTILLO
is_lateral_inspection
false