Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 14, 2019, 08:09 AM
  • C 0553_C 0552_03142019_011957.mp4

Date
03/14/2019
W/O
756627
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00362
PipeID
P04736
Time
1:09 AM
Certificate
U-715-07000770
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K5827
Sewer Name
C JOINT OUTFALL C - UNIT 4D
City
LONG BEACH
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
12
Purpose
Routine Assessment
Project
WO_756627_TV03083_MAR2019
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
30 in.
Width
30 in.
Upstream MH
C 0553
Downstream MH
C 0552
Dir. of Survey
Downstream
Length Surveyed
268.7 ft.
Total Length
268.7 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
3
O&M Quick
4131
O&M Rating
9
Overall Index
3
Overall Quick
Overall Rating
9
Pipe schematic from manhole C 0553 to C 0552
MH: C 0553MH: C 0552downstream0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - C 05530 ft. MWL - Water Level, 25 %of cross sectional area5 ft. MGO - General Observation - LINER6.7 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 8"105.2 ft. DSC - Deposits Settled Compacted, 15 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES201.3 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start266.6 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish268.7 ft. MGO - General Observation - SERVICE CONNECTION AT 3 O' CLOCK AT MH268.7 ft. AMH - Downstream Manhole, Survey Ends - C 0552

Observation photos (1)

  • Deposits Attached Encrustation, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    201.3 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

Observations (10)

DistanceCodeObservation
0MWM
0AMHC 0553
268.7MGOSERVICE CONNECTION AT 3 O' CLOCK AT MH
266.6DAE
201.3DAE
105.2DSC
5MGOLINER
268.7AMHC 0552
6.7TB
0MWL

Properties (8)

additional_info
SC366057
custom_field_two
4
customer
LACSD
datetime
2019-03-14T01:09:29-07:00
documentation
PROPIPE
is_lateral_inspection
false
lining
CIPP
year_laid
36286