Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 20, 2018, 10:26 AM
  • 32 0114_32 0113A_08202018_032658.mp4

Date
08/20/2018
W/O
718360
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00887
PipeID
P25902
Time
3:26 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6006
Sewer Name
32 DISTRICT #32 MAIN TRUNK
City
SANTA CLARITA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
08
Purpose
Routine Assessment
Project
WO_718360_TV32015_AUG2018
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
30 in.
Width
30 in.
Upstream MH
32 0114
Downstream MH
32 0113A
Dir. of Survey
Downstream
Length Surveyed
71.1 ft.
Total Length
71.1 ft.
Structural Index
3
Structural Quick
3B00
Structural Rating
42
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
42
Pipe schematic from manhole 32 0114 to 32 0113A
MH: 32 0114MH: 32 0113Adownstream0 ft. AMH - Upstream Manhole, Survey Begins - 32 01140 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 9 O'CLOCK0 ft. MWM - Water Mark, 10 %of cross sectional area2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start71.1 ft. AMH - Downstream Manhole, Survey Ends - 32 0113A71.1 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 9 O'CLOCK71.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
71.1AMH32 0113A
0AMH32 0114
2SAV
0MWL
0MGOACTIVE CONNECTION AT MH 9 O'CLOCK
71.1MGOACTIVE CONNECTION AT MH 9 O'CLOCK
0MWM
71.1SAV

Properties (5)

additional_info
SC364776
customer
LACSD
datetime
2018-08-20T03:26:41-07:00
documentation
PRO PIPE
is_lateral_inspection
false