Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 25, 2018, 09:50 AM
  • 32 0156_32 0155 _07252018_025033.mp4

Date
07/25/2018
W/O
718360
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00887
PipeID
P19907
Time
2:50 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5880
Sewer Name
32 DISTRICT #32 MAIN TRUNK
City
SANTA CLARITA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
13
Purpose
Routine Assessment
Project
WO_718360_TV32015_AUG2018
Sewer Type
Gravity
Material
NRCP
Shape
Square
Height
15 in.
Width
15 in.
Upstream MH
32 0156
Downstream MH
32 0155
Dir. of Survey
Downstream
Length Surveyed
505.6 ft.
Total Length
505.6 ft.
Structural Index
3
Structural Quick
3S00
Structural Rating
303
O&M Index
2
O&M Quick
2S00
O&M Rating
202
Overall Index
3
Overall Quick
Overall Rating
505
Pipe schematic from manhole 32 0156 to 32 0155
MH: 32 0156MH: 32 0155downstream0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MGO - General Observation - COCKROACHES IN MANHOLE0 ft. AMH - Upstream Manhole, Survey Begins - 32 01562 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start24.1 ft. MGO - General Observation - UNMAPPED MH AT 24'.26.5 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 9 O'CLOCK505.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish505.6 ft. AMH - Downstream Manhole, Survey Ends - 32 0155505.6 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish505.6 ft. MGO - General Observation - COCKROACHES IN MANHOLE

Observation photos (5)

  • General Observation - COCKROACHES IN MANHOLE

    0 ft. - General Observation - COCKROACHES IN MANHOLE

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Observation - UNMAPPED MH AT 24'.

    24.1 ft. - General Observation - UNMAPPED MH AT 24'.

  • General Observation - COCKROACHES IN MANHOLE

    505.6 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (12)

DistanceCodeObservation
2DAGS
505.6DAGS
0MWM
26.5MGOACTIVE CONNECTION AT MH 9 O'CLOCK
0MWL
505.6AMH32 0155
505.6SAP
505.6MGOCOCKROACHES IN MANHOLE
0MGOCOCKROACHES IN MANHOLE
0AMH32 0156
2SAP
24.1MGOUNMAPPED MH AT 24'.

Properties (6)

additional_info
SC359748
custom_field_two
2
customer
LACSD
datetime
2018-07-25T02:50:27-07:00
documentation
PRO PIPE
is_lateral_inspection
false