Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 25, 2018, 07:13 AM
  • 32 0160_32 0159_07252018_001350.mp4

Date
07/25/2018
W/O
718360
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00887
PipeID
P19912
Time
12:13 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5880
Sewer Name
32 DISTRICT #32 MAIN TRUNK
City
SANTA CLARITA
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
13
Purpose
Routine Assessment
Project
WO_718360_TV32015_AUG2018
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
32 0160
Downstream MH
32 0159
Dir. of Survey
Downstream
Length Surveyed
462.7 ft.
Total Length
462.7 ft.
Structural Index
3
Structural Quick
3Q00
Structural Rating
276
O&M Index
2
O&M Quick
2Q00
O&M Rating
184
Overall Index
3
Overall Quick
Overall Rating
460
Pipe schematic from manhole 32 0160 to 32 0159
MH: 32 0160MH: 32 0159downstream0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. MGO - General Observation - MAG COATING THROUGHOUT 70%0 ft. AMH - Upstream Manhole, Survey Begins - 32 01600 ft. MGO - General Observation - COCKROACHES IN MANHOLE0 ft. MWL - Water Level, 5 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. SAP - Surface Aggregate Projecting, from 12 to 12 o'clock, within 8 inches of joint: YES, Start460.9 ft. SAP - Surface Aggregate Projecting, from 12 to 12 o'clock, within 8 inches of joint: YES, Finish461.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish462.7 ft. AMH - Downstream Manhole, Survey Ends - 32 0159462.7 ft. MGO - General Observation - COCKROACHES IN MANHOLE

Observation photos (4)

  • General Observation - COCKROACHES IN MANHOLE

    0 ft. - General Observation - COCKROACHES IN MANHOLE

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 12 to 12 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 12 to 12 o'clock, within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES IN MANHOLE

    462.7 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (11)

DistanceCodeObservation
0MWM
0MGOMAG COATING THROUGHOUT 70%
2DAGS
0AMH32 0160
0MGOCOCKROACHES IN MANHOLE
462.7AMH32 0159
461.2DAGS
2SAP
460.9SAP
462.7MGOCOCKROACHES IN MANHOLE
0MWL

Properties (6)

additional_info
SC359748
custom_field_two
2
customer
LACSD
datetime
2018-07-25T00:13:32-07:00
documentation
PRO PIPE
is_lateral_inspection
false