Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 24, 2018, 08:24 AM
  • 32 0113A_32 0113_08242018_012500.mp4

Date
08/24/2018
W/O
718360
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00887
PipeID
P19859
Time
1:24 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6017
Sewer Name
32 DISTRICT #32 MAIN TRUNK
City
SANTA CLARITA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
08
Purpose
Routine Assessment
Project
WO_718360_TV32015_AUG2018
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
30 in.
Width
30 in.
Upstream MH
32 0113A
Downstream MH
32 0113
Dir. of Survey
Downstream
Length Surveyed
443.8 ft.
Total Length
443.8 ft.
Structural Index
3
Structural Quick
3Q00
Structural Rating
264
O&M Index
2
O&M Quick
2311
O&M Rating
7
Overall Index
3
Overall Quick
Overall Rating
271
Pipe schematic from manhole 32 0113A to 32 0113
MH: 32 0113AMH: 32 0113downstream0 ft. MGO - General Observation - MAG COATING THROUGHOUT 85%0 ft. AMH - Upstream Manhole, Survey Begins - 32 0113A0 ft. MWM - Water Mark, 5 %of cross sectional area0 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 9 O'CLOCK0 ft. MWL - Water Level, 5 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start5.2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start103.2 ft. RFB - Roots Fine Barrell, from 09 to 03 o'clock, within 8 inches of joint: YES216.1 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 4"216.1 ft. RFL - Roots Fine Lateral, at 12 o'clock443.8 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish443.8 ft. AMH - Downstream Manhole, Survey Ends - 32 0113443.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish

Observation photos (4)

  • Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    5.2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Roots Fine Barrell, from 09 to 03 o'clock, within 8 inches of joint: YES

    103.2 ft. - Roots Fine Barrell, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Roots Fine Lateral, at 12 o'clock

    216.1 ft. - Roots Fine Lateral, at 12 o'clock

Observations (13)

DistanceCodeObservation
216.1TB
5.2SAV
0MGOMAG COATING THROUGHOUT 85%
0AMH32 0113A
0MWM
216.1RFL
103.2RFB
0MGOACTIVE CONNECTION AT MH 9 O'CLOCK
0MWL
2DAGS
443.8SAV
443.8AMH32 0113
443.8DAGS

Properties (6)

additional_info
SC364781
custom_field_two
2
customer
LACSD
datetime
2018-08-24T01:24:56-07:00
documentation
PRO PIPE
is_lateral_inspection
false