Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 26, 2018, 07:42 AM
  • 32 0150A_32 0150 _07262018_004409.mp4

Date
07/26/2018
W/O
718360
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00887
PipeID
P19901
Time
12:42 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5881
Sewer Name
32 DISTRICT #32 MAIN TRUNK
City
SANTA CLARITA
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
13
Purpose
Routine Assessment
Project
WO_718360_TV32015_AUG2018
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
32 0150A
Downstream MH
32 0150
Dir. of Survey
Downstream
Length Surveyed
89.9 ft.
Total Length
89.9 ft.
Structural Index
3
Structural Quick
3B00
Structural Rating
51
O&M Index
2
O&M Quick
412B
O&M Rating
38
Overall Index
3
Overall Quick
Overall Rating
89
Pipe schematic from manhole 32 0150A to 32 0150
MH: 32 0150AMH: 32 0150downstream0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 32 0150A0 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 9 O'CLOCK0 ft. MGO - General Observation - COCKROACHES IN MANHOLE0 ft. MGO - General Observation - MAG COATING THROUGHOUT 60%2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start87.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish87.9 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish89.9 ft. MGO - General Observation - COCKROACHES IN MANHOLE89.9 ft. AMH - Downstream Manhole, Survey Ends - 32 0150

Observation photos (4)

  • General Observation - COCKROACHES IN MANHOLE

    0 ft. - General Observation - COCKROACHES IN MANHOLE

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES IN MANHOLE

    89.9 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (12)

DistanceCodeObservation
0MWM
89.9MGOCOCKROACHES IN MANHOLE
0MWL
0AMH32 0150A
0MGOACTIVE CONNECTION AT MH 9 O'CLOCK
87.9DAGS
2SAP
2DAGS
0MGOCOCKROACHES IN MANHOLE
89.9AMH32 0150
0MGOMAG COATING THROUGHOUT 60%
87.9SAP

Properties (6)

additional_info
SC359749
custom_field_two
2
customer
LACSD
datetime
2018-07-26T00:42:57-07:00
documentation
PRO PIPE
is_lateral_inspection
false