Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 26, 2018, 09:16 AM
  • 32 0145_32 0144 _07262018_022428.mp4

Date
07/26/2018
W/O
718360
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00887
PipeID
P19893
Time
2:16 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5881
Sewer Name
32 DISTRICT #32 MAIN TRUNK
City
SANTA CLARITA
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
09
Purpose
Routine Assessment
Project
WO_718360_TV32015_AUG2018
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
32 0145
Downstream MH
32 0144
Dir. of Survey
Downstream
Length Surveyed
569.6 ft.
Total Length
569.6 ft.
Structural Index
3
Structural Quick
3V00
Structural Rating
339
O&M Index
2
O&M Quick
2V00
O&M Rating
226
Overall Index
3
Overall Quick
Overall Rating
565
Pipe schematic from manhole 32 0145 to 32 0144
MH: 32 0145MH: 32 0144downstream0 ft. AMH - Upstream Manhole, Survey Begins - 32 01450 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start58.6 ft. MGO - General Observation - MAG COATING THROUGHOUT 50%568.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish568.1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish569.6 ft. AMH - Downstream Manhole, Survey Ends - 32 0144569.6 ft. MGO - General Observation - COCKROACHES IN MANHOLE

Observation photos (3)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES IN MANHOLE

    569.6 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (10)

DistanceCodeObservation
2DAGS
569.6AMH32 0144
569.6MGOCOCKROACHES IN MANHOLE
0AMH32 0145
0MWM
2SAP
568.1DAGS
58.6MGOMAG COATING THROUGHOUT 50%
0MWL
568.1SAP

Properties (6)

additional_info
SC359749
custom_field_two
2
customer
LACSD
datetime
2018-07-26T02:16:47-07:00
documentation
PRO PIPE
is_lateral_inspection
false