Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 25, 2018, 10:10 AM
  • 32 0155_32 0154 _07252018_031118.mp4

Date
07/25/2018
W/O
718360
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00887
PipeID
P19906
Time
3:10 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5880
Sewer Name
32 DISTRICT #32 MAIN TRUNK
City
SANTA CLARITA
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
13
Purpose
Routine Assessment
Project
WO_718360_TV32015_AUG2018
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
32 0155
Downstream MH
32 0154
Dir. of Survey
Downstream
Length Surveyed
513 ft.
Total Length
513 ft.
Structural Index
3
Structural Quick
3S00
Structural Rating
306
O&M Index
2
O&M Quick
2S00
O&M Rating
204
Overall Index
3
Overall Quick
Overall Rating
510
Pipe schematic from manhole 32 0155 to 32 0154
MH: 32 0155MH: 32 0154downstream0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 32 01552 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start15.4 ft. MGO - General Observation - MAG COATING 75% THROUGHOUT.510.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish510.5 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish513 ft. AMH - Downstream Manhole, Survey Ends - 32 0154513 ft. MGO - General Observation - COCKROACHES IN MANHOLE

Observation photos (3)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES IN MANHOLE

    513 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (10)

DistanceCodeObservation
513AMH32 0154
513MGOCOCKROACHES IN MANHOLE
2DAGS
0MWM
2SAP
510.5DAGS
0MWL
0AMH32 0155
510.5SAP
15.4MGOMAG COATING 75% THROUGHOUT.

Properties (6)

additional_info
SC359748
custom_field_two
2
customer
LACSD
datetime
2018-07-25T03:10:48-07:00
documentation
PRO PIPE
is_lateral_inspection
false