Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 20, 2018, 07:05 AM
  • 02 0264_02 0263A _12192018_230603.mp4

Date
12/19/2018
W/O
740647
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00251
PipeID
P02578
Time
11:05 PM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6278
Sewer Name
02 DOWNEY-BELLFLOWER TRUNK
City
PICO RIVERA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
25
Purpose
Routine Assessment
Project
RFIR_WO_740647_TV02381_DEC2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
02 0264
Downstream MH
02 0263A
Dir. of Survey
Downstream
Length Surveyed
170.1 ft.
Total Length
170.1 ft.
Structural Index
3
Structural Quick
3E00
Structural Rating
96
O&M Index
2
O&M Quick
2F00
O&M Rating
66
Overall Index
2
Overall Quick
Overall Rating
162
Pipe schematic from manhole 02 0264 to 02 0263A
MH: 02 0264MH: 02 0263Adownstream0 ft. AMH - Upstream Manhole, Survey Begins - 02 02640 ft. MWL - Water Level, 25 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start5.7 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start39.2 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"90 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"140.3 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"168 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish168 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish170.1 ft. AMH - Downstream Manhole, Survey Ends - 02 0263A170.1 ft. MGO - General Observation - COCKROACHES IN MANHOLE170.1 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 3 O'CLOCK

Observation photos (3)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    5.7 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES IN MANHOLE

    170.1 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (13)

DistanceCodeObservation
170.1AMH02 0263A
2DAGS
0AMH02 0264
90TF
39.2TFA
170.1MGOCOCKROACHES IN MANHOLE
168DAGS
5.7CM
140.3TFA
0MWL
170.1MGOACTIVE CONNECTION AT MH 3 O'CLOCK
168CM
0MWM

Properties (6)

additional_info
SC365394
custom_field_two
3
customer
LACSD
datetime
2018-12-19T23:05:14-08:00
documentation
PRO PIPE
is_lateral_inspection
false