Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 14, 2018, 06:46 AM
  • 02 0318_02 0317_12132018_224748.mp4

Date
12/13/2018
W/O
740647
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00251
PipeID
P02632
Time
10:46 PM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6274
Sewer Name
02 DOWNEY-BELLFLOWER TRUNK
City
PICO RIVERA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
19A
Purpose
Routine Assessment
Project
RFIR_WO_740647_TV02381_DEC2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
02 0318
Downstream MH
02 0317
Dir. of Survey
Downstream
Length Surveyed
161.7 ft.
Total Length
161.7 ft.
Structural Index
3
Structural Quick
3E00
Structural Rating
93
O&M Index
2
O&M Quick
412E
O&M Rating
69
Overall Index
2
Overall Quick
Overall Rating
162
Pipe schematic from manhole 02 0318 to 02 0317
MH: 02 0318MH: 02 0317downstream0 ft. MWL - Water Level, 40 %of cross sectional area0 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 3 O'CLOCK0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 03182 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start6.3 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start31.2 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 4"61.8 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"61.8 ft. RFL - Roots Fine Lateral, at 12 o'clock125.4 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"160 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish160 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish161.7 ft. MGO - General Observation - COCKROACHES IN MANHOLE161.7 ft. AMH - Downstream Manhole, Survey Ends - 02 0317

Observation photos (4)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    6.3 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Roots Fine Lateral, at 12 o'clock

    61.8 ft. - Roots Fine Lateral, at 12 o'clock

  • General Observation - COCKROACHES IN MANHOLE

    161.7 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (14)

DistanceCodeObservation
2DAGS
6.3CM
0MWL
0MGOACTIVE CONNECTION AT MH 3 O'CLOCK
61.8TFA
0MWM
160CM
31.2TFC
161.7MGOCOCKROACHES IN MANHOLE
161.7AMH02 0317
160DAGS
0AMH02 0318
61.8RFL
125.4TF

Properties (6)

additional_info
SC365390
custom_field_two
3
customer
LACSD
datetime
2018-12-13T22:46:51-08:00
documentation
PRO PIPE
is_lateral_inspection
false