Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 27, 2018, 08:23 AM
  • 22 0755_22 0754 _12272018_004505.mp4

Date
12/27/2018
W/O
740287
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00821
PipeID
P17112
Time
12:23 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6282
Sewer Name
22 PUDDINGSTONE TRUNK, SECTS 1&2
City
SAN DIMAS
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
23
Purpose
Routine Assessment
Project
WO_740287_TV22097_DEC2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
22 0755
Downstream MH
22 0754
Dir. of Survey
Downstream
Length Surveyed
269 ft.
Total Length
269 ft.
Structural Index
3
Structural Quick
3B23
Structural Rating
54
O&M Index
2
O&M Quick
2J11
O&M Rating
107
Overall Index
2
Overall Quick
Overall Rating
161
Pipe schematic from manhole 22 0755 to 22 0754
MH: 22 0755MH: 22 0754downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 22 0754A2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start35.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"49.6 ft. CS - Crack Spiral, from 02 to 04 o'clock, within 8 inches of joint: YES54.6 ft. CS - Crack Spiral, from 07 to 09 o'clock, within 8 inches of joint: YES86.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"104.8 ft. CM - Crack Multiple, from 07 to 12 o'clock, within 8 inches of joint: YES111.1 ft. CL - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES137.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"171 ft. CM - Crack Multiple, from 02 to 05 o'clock, within 8 inches of joint: YES188.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"197.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start239.5 ft. RFL - Roots Fine Lateral, at 02 o'clock239.5 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"267.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish267.7 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish269 ft. AMH - Downstream Manhole, Survey Ends - 22 0754

Observation photos (8)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Spiral, from 02 to 04 o'clock, within 8 inches of joint: YES

    49.6 ft. - Crack Spiral, from 02 to 04 o'clock, within 8 inches of joint: YES

  • Crack Spiral, from 07 to 09 o'clock, within 8 inches of joint: YES

    54.6 ft. - Crack Spiral, from 07 to 09 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 07 to 12 o'clock, within 8 inches of joint: YES

    104.8 ft. - Crack Multiple, from 07 to 12 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

    111.1 ft. - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 02 to 05 o'clock, within 8 inches of joint: YES

    171 ft. - Crack Multiple, from 02 to 05 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    197.2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Roots Fine Lateral, at 02 o'clock

    239.5 ft. - Roots Fine Lateral, at 02 o'clock

Observations (19)

DistanceCodeObservation
197.2CM
2DAGS
267.7DAGS
0MWL
49.6CS
104.8CM
267.7CM
35.7TFC
86.1TFC
269AMH22 0754
0MWM
239.5RFL
111.1CL
188.6TFC
171CM
54.6CS
0AMH22 0754A
137.6TFC
239.5TFA

Properties (6)

additional_info
SC365398
custom_field_two
3
customer
LACSD
datetime
2018-12-27T00:23:45-08:00
documentation
PRO PIPE
is_lateral_inspection
false