Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 19, 2019, 10:11 AM
  • 18 0408_18 0407_03192019_032633.mp4

Date
03/19/2019
W/O
756007
Weather
Dry
Operator/Surveyor
E.RUIZ
Sewer ID
Z00699
PipeID
P14243
Time
3:11 AM
Certificate
U-715-07000753
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6482
Sewer Name
18 SANTA FE STREET RELIEF TRUNK
City
NORWALK
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
21
Purpose
Routine Assessment
Project
RFIR_WO_756007_TV18173_MAR2019
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
18 0408
Downstream MH
18 0407
Dir. of Survey
Downstream
Length Surveyed
453.8 ft.
Total Length
453.8 ft.
Structural Index
3
Structural Quick
3Q00
Structural Rating
273
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
277
Pipe schematic from manhole 18 0408 to 18 0407
MH: 18 0408MH: 18 0407downstream0 ft. MWL - Water Level, 30 %of cross sectional area0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 04084 ft. MGO - General Observation - MAG COAT THROUGHOUT PIPE4 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start9.6 ft. CM - Crack Multiple, from 07 to 10 o'clock, within 8 inches of joint: YES451.6 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish453.8 ft. AMH - Downstream Manhole, Survey Ends - 18 0407

Observation photos (2)

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    4 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Crack Multiple, from 07 to 10 o'clock, within 8 inches of joint: YES

    9.6 ft. - Crack Multiple, from 07 to 10 o'clock, within 8 inches of joint: YES

Observations (8)

DistanceCodeObservation
453.8AMH18 0407
9.6CM
0MWL
4MGOMAG COAT THROUGHOUT PIPE
0MWM
0AMH18 0408
4SAP
451.6SAP

Properties (5)

custom_field_two
2
customer
LACSD
datetime
2019-03-19T03:11:57-07:00
documentation
PROPIPE
is_lateral_inspection
false