Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 20, 2019, 09:30 AM
  • 05 1603_05 1602_03202019_024309.mp4

Date
03/20/2019
W/O
755959
Weather
Dry
Operator/Surveyor
E.RUIZ
Sewer ID
Z00551
PipeID
P06827
Time
2:30 AM
Certificate
U-715-07000753
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6485
Sewer Name
05 203RD STREET TRUNK
City
TORRANCE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
27
Purpose
Routine Assessment
Project
RFIR_WO_755959_TV05176_MAR2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Width
24 in.
Upstream MH
05 1603
Downstream MH
05 1602
Dir. of Survey
Downstream
Length Surveyed
295.7 ft.
Total Length
295.7 ft.
Structural Index
4
Structural Quick
4G00
Structural Rating
156
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
156
Pipe schematic from manhole 05 1603 to 05 1602
MH: 05 1603MH: 05 1602downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 16033.1 ft. FH2 - Fracture Longitudinal Hinge, 2, from 09 to 03 o'clock, within 8 inches of joint: YES, Start51.9 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: YES, 8"103 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 8"154.8 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 8"199.2 ft. FH2 - Fracture Longitudinal Hinge, 2, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish211.1 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 8"267.3 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 8"295.7 ft. AMH - Downstream Manhole, Survey Ends - 05 1602

Observation photos (1)

  • Fracture Longitudinal Hinge, 2, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    3.1 ft. - Fracture Longitudinal Hinge, 2, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (11)

DistanceCodeObservation
0MWL
51.9TFA
295.7AMH05 1602
0MWM
154.8TF
3.1FH2
0AMH05 1603
103TF
199.2FH2
211.1TF
267.3TF

Properties (5)

custom_field_two
2
customer
LACSD
datetime
2019-03-20T02:30:52-07:00
documentation
PROPIPE
is_lateral_inspection
false