Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 3, 2019, 10:28 AM
  • 01 1287_01 1286_05062019_141212.mp4

Date
04/03/2019
W/O
755795
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00207
PipeID
P01583
Time
3:28 AM
Certificate
U-715-07000770
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K5846
Sewer Name
01 CROCKETT BOULEVARD-GLEN AVENUE RELIEF TRUNK
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
13
Purpose
Routine Assessment
Project
RFIR_WO_755795_TV01238_MAR2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
01 1287
Downstream MH
01 1286
Dir. of Survey
Downstream
Length Surveyed
565.4 ft.
Total Length
565.4 ft.
Structural Index
4
Structural Quick
5131
Structural Rating
8
O&M Index
2
O&M Quick
2311
O&M Rating
7
Overall Index
3
Overall Quick
Overall Rating
15
Pipe schematic from manhole 01 1287 to 01 1286
MH: 01 1287MH: 01 1286downstream0 ft. AMH - Upstream Manhole, Survey Begins - 01 12870 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area2.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start3.9 ft. B - Broken, from 08 to 04 o'clock, within 8 inches of joint: YES4.7 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 8"5.4 ft. LR - Alignment Right, 10 %, Start13.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"73.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"89.6 ft. LR - Alignment Right, 10 %, Finish152.8 ft. DSC - Deposits Settled Compacted, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start188.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"191.5 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 6"192.2 ft. DSC - Deposits Settled Compacted, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish239.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"242.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"287.7 ft. TB - Tap Break-In, at 01 o'clock, -, within 8 inches of joint: NO, 6"315.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"338.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"347.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"370.9 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"408.7 ft. TB - Tap Break-In, at 01 o'clock, -, within 8 inches of joint: NO, 6"437 ft. TB - Tap Break-In, at 01 o'clock, -, within 8 inches of joint: NO, 6"449.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"470.3 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"483.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start489.9 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish497.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"516.8 ft. DSC - Deposits Settled Compacted, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start521.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"551 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"563.7 ft. DSC - Deposits Settled Compacted, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish563.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish565.4 ft. AMH - Downstream Manhole, Survey Ends - 01 1286

Observations (34)

DistanceCodeObservation
192.2DSC
152.8DSC
89.6LR
287.7TB
516.8DSC
191.5TF
408.7TB
315.2TF
565.4AMH01 1286
73.4TFC
370.9TB
242.2TF
470.3TB
563.7DSC
0AMH01 1287
0MWM
4.7TB
347.1TF
449.3TF
3.9B
338.4TF
239.6TF
2.5DAGS
521.3TF
497.8TF
489.9CM
0MWL
13.6TF
188.1TF
483.6CM
437TB
551TF
563.7DAGS
5.4LR

Properties (6)

additional_info
SC366083
custom_field_two
1
customer
LACSD
datetime
2019-04-03T03:28:37-07:00
documentation
PROPIPE
is_lateral_inspection
false