Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 18, 2019, 10:39 AM
  • 32 1106_32 1105_01182019_024816.mp4

Date
01/18/2019
W/O
740018
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00841
PipeID
P19556
Time
2:39 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6360
Sewer Name
32 SOLEDAD CANYON TRUNK, SECTS 1,2,3,&4
City
SANTA CLARITA
Loc. details
Parking Lot
Location Code
G
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
11
Purpose
Routine Assessment
Project
RFIR_WO_740018_TV32041_DEC2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
32 1106
Downstream MH
32 1105
Dir. of Survey
Downstream
Length Surveyed
124.3 ft.
Total Length
124.3 ft.
Structural Index
2
Structural Quick
2200
Structural Rating
4
O&M Index
2
O&M Quick
412D
O&M Rating
52
Overall Index
2
Overall Quick
Overall Rating
56
Pipe schematic from manhole 32 1106 to 32 1105
MH: 32 1106MH: 32 1105downstream0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 32 11062 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start44 ft. CS - Crack Spiral, from 09 to 12 o'clock, within 8 inches of joint: YES85.7 ft. CS - Crack Spiral, from 12 to 03 o'clock, within 8 inches of joint: YES123.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish124.3 ft. AMH - Downstream Manhole, Survey Ends - 32 1106

Observation photos (3)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Crack Spiral, from 09 to 12 o'clock, within 8 inches of joint: YES

    44 ft. - Crack Spiral, from 09 to 12 o'clock, within 8 inches of joint: YES

  • Crack Spiral, from 12 to 03 o'clock, within 8 inches of joint: YES

    85.7 ft. - Crack Spiral, from 12 to 03 o'clock, within 8 inches of joint: YES

Observations (8)

DistanceCodeObservation
85.7CS
124.3AMH32 1106
0MWM
44CS
0MWL
123.4DAGS
2DAGS
0AMH32 1106

Properties (6)

additional_info
SC365677
custom_field_two
3
customer
LACSD
datetime
2019-01-18T02:39:03-08:00
documentation
PRO PIPE
is_lateral_inspection
false