Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 22, 2019, 10:16 AM
  • Section#7_15 0839_15 0838__5222019__I0147R.mp4

Date
05/22/2019
W/O
0772703
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00594
PipeID
P12647
Time
3:16 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
I0147R
Sewer Name
15 ARCADIA-SIERRA MADRE TRUNK, SECTS 3&2A
City
SIERRA MADRE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
01
Purpose
Maintenance Related
Project
20190521MDM_ARCADIA_SIERRA_MADRE_TRUNK_SECTS_3_2A
Material
NRCP
Shape
Circular
Height
9.350000381469727 in.
Upstream MH
15 0839
Downstream MH
15 0838
Dir. of Survey
Downstream
Length Surveyed
154.8 ft.
Total Length
154.8 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 15 0839 to 15 0838
MH: 15 0839MH: 15 0838downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 3:20AM0 ft. MWM - Water Mark, 30 %of cross sectional area14.7 ft. MGO - General Observation - 9.4" NRCP + CIPP54.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN57.2 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN126.7 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6" - ACTIVE154.1 ft. MGO - General Observation - MH CONN ACTIVE 9:00154.8 ft. AMH - Downstream Manhole, Survey Ends - 3:35AM

Observation photos (1)

  • General Observation - 9.4" NRCP + CIPP

    14.7 ft. - General Observation - 9.4" NRCP + CIPP

Observations (9)

DistanceCodeObservation
154.1MGOMH CONN ACTIVE 9:00
126.7TBACTIVE
57.2TBOPEN
154.8AMH3:35AM
14.7MGO9.4" NRCP + CIPP
0MWL
0AMH3:20AM
54.1TFOPEN
0MWM

Properties (6)

additional_info
ROOT EVALUATION ONLY
customer
LACSD
datetime
2019-05-22T03:16:36-07:00
documentation
MARTIN,REVELES,OLIVER 111,RUVALCABA
is_lateral_inspection
false
lining
CIPP