Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 21, 2019, 10:02 AM
  • Section#2_15 0844_15 0843__5212019__I0145R.mp4

Date
05/21/2019
W/O
0772703
Weather
Light Rain
Operator/Surveyor
MARTIN
Sewer ID
Z00594
PipeID
P12652
Time
3:02 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
I0145R
Sewer Name
15 ARCADIA-SIERRA MADRE TRUNK, SECTS 3&2A
City
SIERRA MADRE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
01
Purpose
Maintenance Related
Project
20190521MDM_ARCADIA_SIERRA_MADRE_TRUNK_SECTS_3_2A
Material
NRCP
Shape
Circular
Height
9.350000381469727 in.
Upstream MH
15 0844
Downstream MH
15 0843
Dir. of Survey
Downstream
Length Surveyed
310.4 ft.
Total Length
310.4 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 15 0844 to 15 0843
MH: 15 0844MH: 15 0843downstream0 ft. MGO - General Observation - MH CONN OPEN 3:000 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 3:10AM0 ft. MWM - Water Mark, 30 %of cross sectional area8 ft. MGO - General Observation - 9.4" NRCP+ CIPP41.5 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6", 6" - OPEN44.3 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN150.2 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: YES, 6" - OPEN162 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN310.4 ft. AMH - Downstream Manhole, Survey Ends - 3:35AM

Observation photos (1)

  • General Observation - 9.4" NRCP+ CIPP

    8 ft. - General Observation - 9.4" NRCP+ CIPP

Observations (10)

DistanceCodeObservation
0MGOMH CONN OPEN 3:00
162TBOPEN
0MWL
44.3TBOPEN
0AMH3:10AM
310.4AMH3:35AM
8MGO9.4" NRCP+ CIPP
150.2TBOPEN
41.5TBOPEN
0MWM

Properties (6)

additional_info
ROOT EVALUATION ONLY
customer
LACSD
datetime
2019-05-21T03:02:25-07:00
documentation
MARTIN,REVELES,OLIVER 111,RUVALCABA
is_lateral_inspection
false
lining
CIPP