Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 22, 2019, 04:37 PM
  • 16 0572_16 0571_5222019_094151.mp4

Date
05/22/2019
W/O
0772584
Weather
Dry
Operator/Surveyor
FRANKLIN
Sewer ID
Z00659
PipeID
P13623
Time
9:37 AM
Certificate
U-415-06024039
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Jetting
Media Label
G7985
Sewer Name
16 LAMANDA PARK TRUNK
City
PASADENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
11
Purpose
Maintenance Related
Project
2019022DF_LAMANDA_PARK_TRUNK
Material
Reinforced Concrete Pipe
Shape
Circular
Height
22 in.
Upstream MH
16 0572
Downstream MH
16 0571
Dir. of Survey
Downstream
Length Surveyed
259.9 ft.
Total Length
259.9 ft.
Structural Index
4
Structural Quick
5231
Structural Rating
15
O&M Index
2
O&M Quick
2211
O&M Rating
5
Overall Index
3
Overall Quick
Overall Rating
20
Pipe schematic from manhole 16 0572 to 16 0571
MH: 16 0572MH: 16 0571downstream0 ft. AMH - Upstream Manhole, Survey Begins - 9:40 AM0.1 ft. MWM - Water Mark, 15 %of cross sectional area0.1 ft. MWL - Water Level, 10 %of cross sectional area0.1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start13.2 ft. SRC - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES, Start22 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 4"22 ft. MGO - General Observation - VERMIN/RAT 137.6 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 4"57.3 ft. RFB - Roots Fine Barrell, from 02 to 05 o'clock, within 8 inches of joint: YES70.8 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 4" - 5% ROOTS/LATERAL87 ft. RFJ - Roots Fine Joint, from 09 to 03 o'clock, within 8 inches of joint: YESR90.6 ft. RTJ - Roots Tap Joint, at 11 o'clock, 5 %, within 8 inches of joint: YESR90.7 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 4"115.1 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: YES, 4"135.3 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 4" - 10% ROOTS/LATERAL163.5 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 4" - 10% ROOTS/LATERAL184.1 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 4"216.7 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: YES, 4"236.5 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: YES, 4"257.3 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish257.3 ft. SRC - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish257.3 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish257.3 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish259.9 ft. MGO - General Observation - GREASE THROUGHOUT THE REACH (5%)259.9 ft. AMH - Downstream Manhole, Survey Ends - 10:16 AM

Observation photos (13)

  • Water Mark, 15 %of cross sectional area

    0.1 ft. - Water Mark, 15 %of cross sectional area

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    0.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    13.2 ft. - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Observation - VERMIN/RAT 1

    22 ft. - General Observation - VERMIN/RAT 1

  • Roots Fine Barrell, from 02 to 05 o'clock, within 8 inches of joint: YES

    57.3 ft. - Roots Fine Barrell, from 02 to 05 o'clock, within 8 inches of joint: YES

  • Roots Fine Joint, from 09 to 03 o'clock, within 8 inches of joint: YESR

    87 ft. - Roots Fine Joint, from 09 to 03 o'clock, within 8 inches of joint: YESR

  • Roots Tap Joint, at 11 o'clock, 5 %, within 8 inches of joint: YESR

    90.6 ft. - Roots Tap Joint, at 11 o'clock, 5 %, within 8 inches of joint: YESR

  • Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 4"

    90.7 ft. - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 4"

  • Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 4" - 10% ROOTS/LATERAL

    135.3 ft. - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 4" - 10% ROOTS/LATERAL

  • Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 4" - 10% ROOTS/LATERAL

    163.5 ft. - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 4" - 10% ROOTS/LATERAL

  • Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 4"

    184.1 ft. - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 4"

Observations (27)

DistanceCodeObservation
57.3RFB
163.5TFC10% ROOTS/LATERAL
70.8TFC5% ROOTS/LATERAL
257.3SSS
184.1TFC
37.6TFC
257.3SRC
0.1MWM
13.2SRC
22TFC
259.9MGOGREASE THROUGHOUT THE REACH (5%)
257.3SAP
0.1MWL
22MGOVERMIN/RAT 1
259.9AMH10:16 AM
90.6RTJ
115.1TFA
87RFJ
135.3TFC10% ROOTS/LATERAL
0.1SAP
90.7TFC
2SRV
216.7TFA
2SSS
0AMH9:40 AM
236.5TFA
257.3SRV

Properties (7)

additional_info
POST ROOT EVALUATION ONLY
custom_field_three
MINIMAL ROOTS
custom_field_two
2
customer
LACSD
datetime
2019-05-22T09:37:53-07:00
documentation
FRANKLIN, BRAR, CASTILLO
is_lateral_inspection
false