Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 18, 2018, 05:33 AM
  • 05 0106_05 0105 _12172018_215151.mp4

Date
12/17/2018
W/O
740131
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00431
PipeID
P05396
Time
9:33 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6251
Sewer Name
05 DISTRICT #5 MAIN TRUNK
City
HAWTHRONE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
17
Purpose
Routine Assessment
Project
RFIR_WO_740015_TV05147_DEC2018
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
42 in.
Width
42 in.
Upstream MH
05 0106
Downstream MH
05 0105
Dir. of Survey
Downstream
Length Surveyed
321 ft.
Total Length
321 ft.
Structural Index
3
Structural Quick
3L00
Structural Rating
192
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
192
Pipe schematic from manhole 05 0106 to 05 0105
MH: 05 0106MH: 05 0105downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 01062.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.1 ft. MGO - General Observation - MAG COAT54.6 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish54.6 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start321 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish321 ft. MGO - General Observation - CAPPED LATERAL 9 O'CLOCK @ MH321 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK321 ft. AMH - Downstream Manhole, Survey Ends - 05 0105

Observation photos (2)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    54.6 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (12)

DistanceCodeObservation
2.1SAV
2.1MGOMAG COAT
321SAP
321MGOCAPPED LATERAL 9 O'CLOCK @ MH
54.6SAV
0MWM
0MGOCONNECTION AT MH 3 O'CLOCK
0MWL
321MGOCONNECTION AT MH 3 O'CLOCK
321AMH05 0105
0AMH05 0106
54.6SAP

Properties (5)

additional_info
SC365484
custom_field_two
2
customer
LACSD
datetime
2018-12-17T21:33:51-08:00
is_lateral_inspection
false