Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 12, 2018, 08:55 AM
  • 05 0162_05 0161 _12122018_011905.mp4

Date
12/12/2018
W/O
740131
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00431
PipeID
P05454
Time
12:55 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6247
Sewer Name
05 DISTRICT #5 MAIN TRUNK
City
HAWTHRONE
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
10
Purpose
Routine Assessment
Project
RFIR_WO_740015_TV05147_DEC2018
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Rectangular
Height
30 in.
Width
30 in.
Upstream MH
05 0162
Downstream MH
05 0161
Dir. of Survey
Downstream
Length Surveyed
168.8 ft.
Total Length
168.8 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole 05 0162 to 05 0161
MH: 05 0162MH: 05 0161downstream0 ft. AMH - Upstream Manhole, Survey Begins - 05 01620 ft. MGO - General Observation - SERVICE CONNECTION AT 6 O' CLOCK AT MH0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. MWL - Water Level, 25 %of cross sectional area2.1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start168.8 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish168.8 ft. MGO - General Observation - SERVICE CONNECTION AT 9 O'CLOCK AT MH168.8 ft. AMH - Downstream Manhole, Survey Ends - 05 0161

Observation photos (1)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
2.1SAP
0AMH05 0162
168.8SAP
168.8MGOSERVICE CONNECTION AT 9 O'CLOCK AT MH
0MGOSERVICE CONNECTION AT 6 O' CLOCK AT MH
0MWM
0MWL
168.8AMH05 0161

Properties (5)

additional_info
SC365480
custom_field_two
2
customer
LACSD
datetime
2018-12-12T00:55:56-08:00
is_lateral_inspection
false