Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 29, 2019, 07:08 AM
  • 29 0080_29 0079 _01282019_233046.mpg

Date
01/28/2019
W/O
745716
Weather
Dry
Operator/Surveyor
E.RUIZ
Sewer ID
Z00265
PipeID
P23860
Time
11:08 PM
Certificate
U-715-07000753
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K5354
Sewer Name
29 33RD STREET TRUNK
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
01
Purpose
Routine Assessment
Project
RFIR_WO_745716_TV29073_JAN2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
29 0080
Downstream MH
29 0079
Dir. of Survey
Downstream
Length Surveyed
335.9 ft.
Total Length
335.9 ft.
Structural Index
4
Structural Quick
4L00
Structural Rating
264
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
264
Pipe schematic from manhole 29 0080 to 29 0079
MH: 29 0080MH: 29 0079downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 29 00800 ft. MGO - General Observation - CONNECTION AT MH 9 OCLOCK3.9 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start47.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"51.1 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6" - ROOTS71.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"83.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"146.3 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6" - ROOTS232.5 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"295.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"298 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"335.2 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish335.9 ft. AMH - Downstream Manhole, Survey Ends - 29 0079335.9 ft. MGO - General Observation - CONNECTION AT MH 9 OCLOCK

Observation photos (1)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.9 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (16)

DistanceCodeObservation
3.9FM
0MWM
51.1TFAROOTS
0MWL
71.6TF
335.2FM
47.5TF
335.9AMH29 0079
0AMH29 0080
295.9TF
335.9MGOCONNECTION AT MH 9 OCLOCK
146.3TFAROOTS
298TF
232.5TBA
83.2TF
0MGOCONNECTION AT MH 9 OCLOCK

Properties (4)

custom_field_two
2
customer
LACSD
datetime
2019-01-28T23:08:43-08:00
is_lateral_inspection
false