Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 29, 2019, 08:12 AM
  • 29 0082_29 0081 _01292019_003505.mpg

Date
01/29/2019
W/O
745716
Weather
Dry
Operator/Surveyor
E.RUIZ
Sewer ID
Z00265
PipeID
P23862
Time
12:12 AM
Certificate
U-715-07000753
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K5354
Sewer Name
29 33RD STREET TRUNK
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
01
Purpose
Routine Assessment
Project
RFIR_WO_745716_TV29073_JAN2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
29 0081
Downstream MH
29 0082
Dir. of Survey
Upstream
Length Surveyed
329.2 ft.
Total Length
329.2 ft.
Structural Index
4
Structural Quick
4L00
Structural Rating
260
O&M Index
3
O&M Quick
3100
O&M Rating
3
Overall Index
4
Overall Quick
Overall Rating
263
Pipe schematic from manhole 29 0081 to 29 0082
MH: 29 0081MH: 29 0082upstream0 ft. AMH - Upstream Manhole, Survey Ends - 29 00820 ft. MGO - General Observation - CONNECTION AT MH 3 OCLOCK1.9 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish21.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"24.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"86.5 ft. TBI - Tap Break-In Intruding, at 11 o'clock, -, -, within 8 inches of joint: YES, 1", 6"93.7 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"169.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"312.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"326.8 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start329.2 ft. MWM - Water Mark, 25 %of cross sectional area329.2 ft. AMH - Downstream Manhole, Survey Begins - 29 0081329.2 ft. MWL - Water Level, 15 %of cross sectional area

Observation photos (1)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.4 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (13)

DistanceCodeObservation
159.4TFC
242.7TBI
235.5TFA
307.5TF
329.2AMH29 0082
305.1TF
329.2MGOCONNECTION AT MH 3 OCLOCK
0MWM
2.4FM
16.8TF
327.3FM
0AMH29 0081
0MWL

Properties (4)

custom_field_two
2
customer
LACSD
datetime
2019-01-29T00:12:00-08:00
is_lateral_inspection