Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 7, 2019, 12:02 PM
  • 01 0532_01 0531_01072019_041543.mp4

Date
01/07/2019
W/O
740024
Weather
Heavy Rain
Operator/Surveyor
B.FUGATE
Sewer ID
Z00206
PipeID
P01019
Time
4:02 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6314
Sewer Name
01 CROCKETT BOULEVARD-GLEN AVENUE TRUNK
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
10
Purpose
Routine Assessment
Project
RFIR_WO_740024_TV01017_DEC2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
01 0532
Downstream MH
01 0531
Dir. of Survey
Downstream
Length Surveyed
330.5 ft.
Total Length
330.5 ft.
Structural Index
4
Structural Quick
4L00
Structural Rating
260
O&M Index
1
O&M Quick
1100
O&M Rating
1
Overall Index
4
Overall Quick
Overall Rating
261
Pipe schematic from manhole 01 0532 to 01 0531
MH: 01 0532MH: 01 0531downstream0 ft. AMH - Upstream Manhole, Survey Begins - 01 05320 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area3.1 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start26.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"49.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"49.6 ft. RFL - Roots Fine Lateral, at 10 o'clock76.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"90.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"111.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"132.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"161.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"185.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"212.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"242 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"265.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"292.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"318.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"330.5 ft. AMH - Downstream Manhole, Survey Ends - 01 0531330.5 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (1)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.1 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (20)

DistanceCodeObservation
265.7TF
132.2TF
49.6RFL
49.5TF
330.5AMH01 0531
161.7TFC
212.5TF
330.5FM
0AMH01 0532
185.7TFC
3.1FM
242TF
0MWM
90.8TF
111.5TFC
0MWL
76.3TF
292.3TF
26.1TF
318.8TFC

Properties (5)

additional_info
SC365498
custom_field_two
2
customer
LACSD
datetime
2019-01-07T04:02:11-08:00
is_lateral_inspection
false