Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 27, 2019, 04:45 AM
  • 29 0738_29 0317 _03262019_221538.mp4

Date
03/26/2019
W/O
755793
Weather
Dry
Operator/Surveyor
E.RUIZ
Sewer ID
Z01017
PipeID
P24350
Time
9:45 PM
Certificate
U-715-07000753
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6498
Sewer Name
29 PACIFIC COAST HIGHWAY SEWER
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
04
Purpose
Routine Assessment
Project
RFIR_WO_755793_TV29085_MAR2019
Sewer Type
Gravity
Material
CON
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
29 0317
Downstream MH
29 0738
Dir. of Survey
Upstream
Length Surveyed
165.3 ft.
Total Length
165.3 ft.
Structural Index
3
Structural Quick
4434
Structural Rating
34
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
34
Pipe schematic from manhole 29 0317 to 29 0738
MH: 29 0317MH: 29 0738upstream0 ft. AMH - Upstream Manhole, Survey Ends - 29 07382.7 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish8.8 ft. FM - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES37.9 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 8"44.4 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES46.7 ft. CL - Crack Longitudinal, at 08 o'clock, within 8 inches of joint: YES59.7 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES63.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"77.3 ft. FS - Fracture Spiral, from 10 to 11 o'clock, within 8 inches of joint: YES79.7 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"86.3 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"90.5 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES98.2 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES114.8 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"116.2 ft. FH2 - Fracture Longitudinal Hinge, 2, from 09 to 03 o'clock, within 8 inches of joint: YES140.5 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"159.3 ft. FM - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES162.4 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES162.4 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start165.3 ft. MWM - Water Mark, 10 %of cross sectional area165.3 ft. AMH - Downstream Manhole, Survey Begins - 29 0317165.3 ft. MWL - Water Level, 5 %of cross sectional area

Observation photos (11)

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    2.9 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.9 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    6 ft. - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal Hinge, 2, from 09 to 03 o'clock, within 8 inches of joint: YES

    49.1 ft. - Fracture Longitudinal Hinge, 2, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

    67.1 ft. - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    74.8 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Fracture Spiral, from 10 to 11 o'clock, within 8 inches of joint: YES

    88 ft. - Fracture Spiral, from 10 to 11 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

    105.6 ft. - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 08 o'clock, within 8 inches of joint: YES

    118.6 ft. - Crack Longitudinal, at 08 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    120.9 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    156.5 ft. - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

Observations (22)

DistanceCodeObservation
156.5FM
0MWM
6FM
162.6SAP
0AMH29 0317
85.6TBA
67.1CL
79TFA
2.9FM
120.9FL
74.8FL
102.1TF
165.3AMH29 0738
49.1FH2
88FS
118.6CL
0MWL
127.4TFA
2.9SAP
50.5TFA
105.6CL
24.8TFA

Properties (4)

custom_field_two
2
customer
LACSD
datetime
2019-03-26T21:45:46-07:00
is_lateral_inspection
false