Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 11, 2019, 09:56 AM
  • J 0046_J 0044 _02112019_020839.mp4

Date
02/11/2019
W/O
745313
Weather
Dry
Operator/Surveyor
E.RUIZ
Sewer ID
Z00062
PipeID
P11623
Time
1:56 AM
Certificate
U-715-07000753
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6269
Sewer Name
J JOINT OUTFALL J - UNIT 2C
City
LOMITA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
32
Purpose
Routine Assessment
Project
RFIR_WO_745313_TV05287_JAN2019
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Square
Height
42 in.
Width
42 in.
Upstream MH
J 0046
Downstream MH
J 0044
Dir. of Survey
Downstream
Length Surveyed
359.1 ft.
Total Length
359.1 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
4
Overall Quick
Overall Rating
7
Pipe schematic from manhole J 0046 to J 0044
MH: J 0046MH: J 0044downstream0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. MWL - Water Level, 45 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - J 00460 ft. MWM - Water Mark, 55 %of cross sectional area5.2 ft. MGO - General Observation - MAG COAT5.3 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start354.8 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish359.1 ft. AMH - Downstream Manhole, Survey Ends - J 0044359.1 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK

Observation photos (1)

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    5.3 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (9)

DistanceCodeObservation
354.8SAP
0MGOCONNECTION AT MH 9 O'CLOCK
5.3SAP
5.2MGOMAG COAT
0MWL
359.1AMHJ 0044
0AMHJ 0046
359.1MGOCONNECTION AT MH 9 O'CLOCK
0MWM

Properties (4)

custom_field_two
2
customer
LACSD
datetime
2019-02-11T01:56:14-08:00
is_lateral_inspection
false