Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 3, 2019, 08:22 AM
  • H 0613_H JOINT_532019_014546.mp4

Date
05/03/2019
W/O
0769645
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00190
PipeID
P20358
Time
1:22 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1195
Sewer Name
H JOINT OUTFALL H - UNIT 8G
City
WEST COVINA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
24
Purpose
Routine Assessment
Project
20190503MDM_JOINT_OUTFALL_H_UNIT_8G
Material
Reinforced Concrete Pipe
Shape
Circular
Height
48 in.
Upstream MH
H 0613
Downstream MH
H JOINT
Dir. of Survey
Downstream
Length Surveyed
394.8 ft.
Total Length
394.8 ft.
Structural Index
2
Structural Quick
3324
Structural Rating
17
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
17
Pipe schematic from manhole H 0613 to H JOINT
MH: H 0613MH: H JOINTdownstream0 ft. MGO - General Observation - 90% MAG COAT START0 ft. AMH - Upstream Manhole, Survey Begins - 1:45AM0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO, Start - SEVERE AGG SPORATIC2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE15.1 ft. SAV - Surface Aggregate Visible, from 01 to 03 o'clock, within 8 inches of joint: YES - SEVERE AGG28 ft. SSS - Surface Spalling, from 04 to 02 o'clock, within 8 inches of joint: NO - BLISTERING CONCRETE31.9 ft. SAV - Surface Aggregate Visible, from 11 to 01 o'clock, within 8 inches of joint: NO - SEVERE AGG76.8 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING PEELING CONCRETE189.7 ft. SSS - Surface Spalling, from 08 to 12 o'clock, within 8 inches of joint: NO - PEELING CONCRETE394.2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - BLISTERING PEELING CONCRETE394.2 ft. MGO - General Observation - 90% MAG COAT FINISH394.2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO, Finish - SEVERE AGG SPORATIC394.8 ft. AMH - Downstream Manhole, Survey Ends - 2:20AM

Observation photos (8)

  • General Observation - 90% MAG COAT START

    0 ft. - General Observation - 90% MAG COAT START

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO, Start - SEVERE AGG SPORATIC

    2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO, Start - SEVERE AGG SPORATIC

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

  • Surface Aggregate Visible, from 01 to 03 o'clock, within 8 inches of joint: YES - SEVERE AGG

    15.1 ft. - Surface Aggregate Visible, from 01 to 03 o'clock, within 8 inches of joint: YES - SEVERE AGG

  • Surface Spalling, from 04 to 02 o'clock, within 8 inches of joint: NO - BLISTERING CONCRETE

    28 ft. - Surface Spalling, from 04 to 02 o'clock, within 8 inches of joint: NO - BLISTERING CONCRETE

  • Surface Aggregate Visible, from 11 to 01 o'clock, within 8 inches of joint: NO - SEVERE AGG

    31.9 ft. - Surface Aggregate Visible, from 11 to 01 o'clock, within 8 inches of joint: NO - SEVERE AGG

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING PEELING CONCRETE

    76.8 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING PEELING CONCRETE

  • Surface Spalling, from 08 to 12 o'clock, within 8 inches of joint: NO - PEELING CONCRETE

    189.7 ft. - Surface Spalling, from 08 to 12 o'clock, within 8 inches of joint: NO - PEELING CONCRETE

Observations (15)

DistanceCodeObservation
189.7SSSPEELING CONCRETE
394.8AMH2:20AM
0MGO90% MAG COAT START
76.8SSSBLISTERING PEELING CONCRETE
394.2SSSBLISTERING PEELING CONCRETE
15.1SAVSEVERE AGG
394.2MGO90% MAG COAT FINISH
2SAVSEVERE AGG SPORATIC
0AMH1:45AM
28SSSBLISTERING CONCRETE
31.9SAVSEVERE AGG
394.2SAVSEVERE AGG SPORATIC
2SSSBLISTERING PEELING CONCRETE
0MWL
0MWM

Properties (7)

custom_field_three
SEVERE AGG SPORATIC - 90% MAG COAT
custom_field_two
4
customer
LACSD
datetime
2019-05-03T01:22:22-07:00
documentation
MARTIN,REVELES,OLIVER 111,RUVALCABA
is_lateral_inspection
false
year_laid
19740618