H 0613_H JOINT_532019_014546.mp4
0 ft. - General Observation - 90% MAG COAT START
2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO, Start - SEVERE AGG SPORATIC
2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE
15.1 ft. - Surface Aggregate Visible, from 01 to 03 o'clock, within 8 inches of joint: YES - SEVERE AGG
28 ft. - Surface Spalling, from 04 to 02 o'clock, within 8 inches of joint: NO - BLISTERING CONCRETE
31.9 ft. - Surface Aggregate Visible, from 11 to 01 o'clock, within 8 inches of joint: NO - SEVERE AGG
76.8 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING PEELING CONCRETE
189.7 ft. - Surface Spalling, from 08 to 12 o'clock, within 8 inches of joint: NO - PEELING CONCRETE
| Distance | Code | Observation |
|---|---|---|
| 189.7 | SSS | PEELING CONCRETE |
| 394.8 | AMH | 2:20AM |
| 0 | MGO | 90% MAG COAT START |
| 76.8 | SSS | BLISTERING PEELING CONCRETE |
| 394.2 | SSS | BLISTERING PEELING CONCRETE |
| 15.1 | SAV | SEVERE AGG |
| 394.2 | MGO | 90% MAG COAT FINISH |
| 2 | SAV | SEVERE AGG SPORATIC |
| 0 | AMH | 1:45AM |
| 28 | SSS | BLISTERING CONCRETE |
| 31.9 | SAV | SEVERE AGG |
| 394.2 | SAV | SEVERE AGG SPORATIC |
| 2 | SSS | BLISTERING PEELING CONCRETE |
| 0 | MWL | — |
| 0 | MWM | — |