G 0113_G 0086_572019_015253.mp4
2 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - BROKEN MISSING REBAR
2 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG AREAS OF MISSING TILES
8.9 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - BROKEN MISSING REBAR
66.1 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - BROKEN MISSING REBAR
96.5 ft. - Water Mark, 50 %of cross sectional area
158 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - MISSING REBAR
238.5 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - BROKEN REBAR
| Distance | Code | Observation |
|---|---|---|
| 0 | MGO | Conn. @ Mh, 3 O' Clock. Active |
| 2 | SRC | BROKEN MISSING REBAR |
| 318.3 | MGO | 80% MISSING TILES FINISH |
| 2 | MGO | 90% TILES MISSING |
| 66.1 | SRC | BROKEN MISSING REBAR |
| 96.5 | MWM | — |
| 0 | MWL | — |
| 318.3 | MGO | Conn. @ Mh, 3 O' Clock. Active LARGE INCOMING |
| 238.5 | SRC | BROKEN REBAR |
| 318.3 | SRC | LONG & CIRCUM REBAR CORRODED BROKEN MISSING |
| 0 | AMH | 1:50AM |
| 318.9 | AMH | 2:20AM |
| 0 | MWM | — |
| 8.9 | SRC | BROKEN MISSING REBAR |
| 2 | SAM | SEVERE AGG AREAS OF MISSING TILES |
| 0 | MGO | Conn. @ Mh, 9 O' Clock. Active |
| 318.3 | SAM | SEVERE AGG AREAS OF MISSING TILES |
| 96.5 | MWL | — |
| 158 | SRC | MISSING REBAR |