Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 7, 2019, 07:39 AM
  • G 0114_G 0113_572019_005535.mp4

Date
05/07/2019
W/O
0767444
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z01180
PipeID
P01441
Time
12:39 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1198
Sewer Name
G JOINT OUTFALL G - UNIT 8
City
COMPTON
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
21
Purpose
Capital Improvement Program Assesment
Project
20190503MDM_JOINT_OUTFALL_G_UNIT_8
Material
RCP-CTL
Shape
Circular
Height
48 in.
Upstream MH
G 0114
Downstream MH
G 0113
Dir. of Survey
Downstream
Length Surveyed
290.9 ft.
Total Length
290.9 ft.
Structural Index
5
Structural Quick
5741
Structural Rating
39
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
5
Overall Quick
Overall Rating
43
Pipe schematic from manhole G 0114 to G 0113
MH: G 0114MH: G 0113downstream0 ft. MWM - Water Mark, 70 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 12:55AM0 ft. MWL - Water Level, 60 %of cross sectional area2 ft. MGO - General Observation - 90% MISSING TILES START2 ft. SAM - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG AREASA OF MISSING TILES2 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - LONG & CIRCUM REBAR CORRODED MISSING2 ft. MGO - General Observation - 70% MAG COAT12.1 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - LONG CIRCUM REBAR15.8 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - MISSINGT REBAR85.6 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - CORRODED MISSING REBAR124.6 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - BROKEN MISSING REBAR127.4 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - BROKEN MISSING REBAR183.7 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - BROKEN REBAR290.2 ft. MGO - General Observation - 70% MAG COAT FINISH290.2 ft. MGO - General Observation - 90% MISSING TILES FINISH290.2 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Finish - LONG & CIRCUM REBAR CORRODED BROKEN MISSING290.2 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active290.2 ft. SAM - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG AREAS OF MISSING TILES290.2 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active290.9 ft. AMH - Downstream Manhole, Survey Ends - 1:35AM

Observation photos (10)

  • General Observation - 90% MISSING TILES START

    2 ft. - General Observation - 90% MISSING TILES START

  • Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG AREASA OF MISSING TILES

    2 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG AREASA OF MISSING TILES

  • Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - LONG & CIRCUM REBAR CORRODED  MISSING

    2 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - LONG & CIRCUM REBAR CORRODED MISSING

  • General Observation - 70% MAG COAT

    2 ft. - General Observation - 70% MAG COAT

  • Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - LONG CIRCUM REBAR

    12.1 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - LONG CIRCUM REBAR

  • Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - MISSINGT REBAR

    15.8 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - MISSINGT REBAR

  • Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - CORRODED MISSING REBAR

    85.6 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - CORRODED MISSING REBAR

  • Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - BROKEN MISSING REBAR

    124.6 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - BROKEN MISSING REBAR

  • Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - BROKEN MISSING REBAR

    127.4 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - BROKEN MISSING REBAR

  • Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - BROKEN REBAR

    183.7 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - BROKEN REBAR

Observations (20)

DistanceCodeObservation
85.6SRCCORRODED MISSING REBAR
127.4SRCBROKEN MISSING REBAR
290.2MGO70% MAG COAT FINISH
0MWM
2MGO90% MISSING TILES START
0AMH12:55AM
124.6SRCBROKEN MISSING REBAR
290.2MGO90% MISSING TILES FINISH
2SAMSEVERE AGG AREASA OF MISSING TILES
2SRCLONG & CIRCUM REBAR CORRODED MISSING
2MGO70% MAG COAT
290.2SRCLONG & CIRCUM REBAR CORRODED BROKEN MISSING
15.8SRCMISSINGT REBAR
290.2MGOConn. @ Mh, 9 O' Clock. Active
12.1SRCLONG CIRCUM REBAR
290.9AMH1:35AM
0MWL
290.2SAMSEVERE AGG AREAS OF MISSING TILES
290.2MGOConn. @ Mh, 3 O' Clock. Active
183.7SRCBROKEN REBAR

Properties (6)

custom_field_three
LONG CIRCUM REBAR CORRODED BROKEN MISSING
custom_field_two
1
customer
LACSD
datetime
2019-05-07T00:39:37-07:00
documentation
MARTIN,REVELES,OLIVER 111,RUVALCABA
is_lateral_inspection
false