Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 3, 2019, 11:58 AM
  • G 0118_G 0117_532019_051101.mp4

Date
05/03/2019
W/O
0767444
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z01180
PipeID
P01445
Time
4:58 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1196
Sewer Name
G JOINT OUTFALL G - UNIT 8
City
COMPTON
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
21
Purpose
Capital Improvement Program Assesment
Project
20190503MDM_JOINT_OUTFALL_G_UNIT_8
Material
RCP-CTL
Shape
Circular
Height
48 in.
Upstream MH
G 0118
Downstream MH
G 0117
Dir. of Survey
Downstream
Length Surveyed
358.9 ft.
Total Length
358.9 ft.
Structural Index
5
Structural Quick
5541
Structural Rating
29
O&M Index
5
O&M Quick
5100
O&M Rating
5
Overall Index
5
Overall Quick
Overall Rating
34
Pipe schematic from manhole G 0118 to G 0117
MH: G 0118MH: G 0117downstream0 ft. MWL - Water Level, 60 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWM - Water Mark, 80 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 5:15AM2 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - LONG & CIRCUM REBAR CORRODED & MISSING2 ft. MGO - General Observation - 95% MISSING TILES 10:00 TO 2:002 ft. SAM - Surface Aggregate Missing, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG8 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - CORRODED MISSING REBAR39.3 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES - CORRODED MISSING REBAR48.9 ft. MGO - General Observation - 70% MISSING TILES100.8 ft. MGO - General Observation - 60% MAG COAT THROUGHOUT REACH112.7 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - CORRODED MISSING REBAR123 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - CORRODED MISSING REBAR160.5 ft. MGO - General Observation - 40% MISSING TILES START187 ft. MGO - General Observation - 80% MISSING TILES START358.5 ft. SAM - Surface Aggregate Missing, from 10 to 02 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG358.5 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. OPEN358.5 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Finish - LONG & CIRCUM REBAR CORRODED & MISSING358.5 ft. MGO - General Observation - 60% MAG COAT FINISH358.5 ft. MGO - General Observation - 80% MISSING TILES FINISH358.9 ft. AMH - Downstream Manhole, Survey Ends - 6:00AM

Observation photos (10)

  • Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - LONG & CIRCUM REBAR CORRODED & MISSING

    2 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - LONG & CIRCUM REBAR CORRODED & MISSING

  • General Observation - 95% MISSING TILES 10:00 TO 2:00

    2 ft. - General Observation - 95% MISSING TILES 10:00 TO 2:00

  • Surface Aggregate Missing, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

    2 ft. - Surface Aggregate Missing, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

  • Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - CORRODED MISSING REBAR

    8 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - CORRODED MISSING REBAR

  • Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES - CORRODED MISSING REBAR

    39.3 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES - CORRODED MISSING REBAR

  • General Observation - 60% MAG COAT THROUGHOUT REACH

    100.8 ft. - General Observation - 60% MAG COAT THROUGHOUT REACH

  • Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - CORRODED MISSING REBAR

    112.7 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - CORRODED MISSING REBAR

  • Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - CORRODED MISSING REBAR

    123 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - CORRODED MISSING REBAR

  • General Observation - 40% MISSING TILES START

    160.5 ft. - General Observation - 40% MISSING TILES START

  • General Observation - 80% MISSING TILES START

    187 ft. - General Observation - 80% MISSING TILES START

Observations (21)

DistanceCodeObservation
0MWL
0MWM
39.3SRCCORRODED MISSING REBAR
8SRCCORRODED MISSING REBAR
123SRCCORRODED MISSING REBAR
2SRCLONG & CIRCUM REBAR CORRODED & MISSING
2MGO95% MISSING TILES 10:00 TO 2:00
358.5SAMSEVERE AGG
358.5MGOConn. @ Mh, 9 O' Clock. OPEN
48.9MGO70% MISSING TILES
100.8MGO60% MAG COAT THROUGHOUT REACH
160.5MGO40% MISSING TILES START
358.5SRCLONG & CIRCUM REBAR CORRODED & MISSING
0MWM
358.5MGO60% MAG COAT FINISH
0AMH5:15AM
112.7SRCCORRODED MISSING REBAR
2SAMSEVERE AGG
358.9AMH6:00AM
187MGO80% MISSING TILES START
358.5MGO80% MISSING TILES FINISH

Properties (6)

custom_field_three
LONG & CIRCUM REBAR CORRODED & MISSING
custom_field_two
1
customer
LACSD
datetime
2019-05-03T04:58:07-07:00
documentation
MARTIN,REVELES,OLIVER 111,RUVALCABA
is_lateral_inspection
false