- Date
- 03/21/2019
- W/O
- 0759728
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00247
- PipeID
- P04406
- Time
- 12:51 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Heavy Cleaning
- Media Label
- H1157
- Sewer Name
- 02 DOUGLAS AVENUE RELIEF TRUNK
- City
- LOS ANGLES
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 08
- Purpose
- Capital Improvement Program Assesment
- Project
- 20190321MDM_DOUGLAS_AVENUE_RELIEF_TRUNK
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 8 in.
- Upstream MH
- 02 2090
- Downstream MH
- 02 2089
- Dir. of Survey
- Downstream
- Length Surveyed
- 261.7 ft.
- Total Length
- 261.7 ft.
- Structural Index
- 2
- Structural Quick
- 3224
- Structural Rating
- 14
- O&M Index
- 3
- O&M Quick
- 4222
- O&M Rating
- 12
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 26
Pipe schematic from manhole 02 2090 to 02 2089 Observation photos (5)

2 ft. - Fracture Circumferential, from 02 to 05 o'clock, within 8 inches of joint: NO - MODERATE

33.5 ft. - Deposits Attached Other, 5 %of cross sectional area, from 02 to 03 o'clock, , within 8 inches of joint: YES - POSSIBLE CONCRETE

33.6 ft. - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open-20% POSSIBLE CONCRETE

117.2 ft. - Water Level, Sag in pipe, 50 %of cross sectional area - START

169 ft. - General Observation - 8" VCP