Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 18, 2019, 11:30 AM
  • C 0119B_A 0247_3182019_060143.mp4

Date
03/18/2019
W/O
0759956
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00127
PipeID
P09642
Time
4:30 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1153
Sewer Name
C JOINT OUTFALL C - UNIT 4B
City
LONG BEACH
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
20
Purpose
Capital Improvement Program Assesment
Project
20190318MDM_JOINT_OUTFALL_C_UNIT_4B
Material
Reinforced Concrete Pipe
Shape
Circular
Height
48 in.
Upstream MH
C 0119B
Downstream MH
A 0247
Dir. of Survey
Downstream
Length Surveyed
19.6 ft.
Total Length
19.6 ft.
Structural Index
5
Structural Quick
5241
Structural Rating
14
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
5
Overall Quick
Overall Rating
14
Pipe schematic from manhole C 0119B to A 0247
MH: C 0119BMH: A 0247downstream0 ft. AMH - Upstream Manhole, Survey Begins - 5:55AM0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area2 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG2 ft. MGO - General Observation - ZOOM 15'15 ft. SRC - Surface Reinforcement Corroded, from 01 to 04 o'clock, within 8 inches of joint: NO - CIRCUM REBAR15 ft. SRC - Surface Reinforcement Corroded, from 01 to 04 o'clock, within 8 inches of joint: NO - CIRCUM REBAR19 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG19.6 ft. AMH - Downstream Manhole, Survey Ends - 6:10AM

Observation photos (3)

  • Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

    2 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

  • Surface Reinforcement Corroded, from 01 to 04 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

    15 ft. - Surface Reinforcement Corroded, from 01 to 04 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

  • Surface Reinforcement Corroded, from 01 to 04 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

    15 ft. - Surface Reinforcement Corroded, from 01 to 04 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

Observations (9)

DistanceCodeObservation
15SRCCIRCUM REBAR
0AMH5:55AM
2SAMSEVERE AGG
0MWL
2MGOZOOM 15'
19SAMSEVERE AGG
0MWM
15SRCCIRCUM REBAR
19.6AMH6:10AM

Properties (6)

custom_field_three
CIRCUM REBAR CORRODED
custom_field_two
2
customer
LACSD
datetime
2019-03-18T04:30:09-07:00
documentation
MARTIN,OLIVER 111,CASTILLO
is_lateral_inspection
false