- Date
- 03/13/2019
- W/O
- 0760483
- Weather
- Dry
- Operator/Surveyor
- FRANKLIN
- Sewer ID
- Z00285
- PipeID
- P04603
- Time
- 10:17 AM
- Certificate
- U-415-06024039
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- G7940
- Sewer Name
- 02 MONTEBELLO-RANDOLPH TRUNK
- City
- COMMERCE
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 20
- Purpose
- Maintenance Related
- Project
- 20190313DF_MONTEBELLO_RANDOLH_TRUNK
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 15 in.
- Upstream MH
- 02 1112
- Downstream MH
- 02 1111
- Dir. of Survey
- Downstream
- Length Surveyed
- 235.3 ft.
- Total Length
- 235.3 ft.
- Structural Index
- 3
- Structural Quick
- 3221
- Structural Rating
- 8
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 8
Pipe schematic from manhole 02 1112 to 02 1111 Observation photos (4)

2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

31.9 ft. - Fracture Spiral, from 12 to 01 o'clock, within 8 inches of joint: YES

195.5 ft. - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4", 4" - Unkown/90% GREASE LATERAL