05 1010_05 1009_3152019_040709.mp4
2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE
2 ft. - General Observation - MAG COAT 90% START
13.2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - PEELING CONCRETE
81.5 ft. - Surface Aggregate Visible, from 08 to 10 o'clock, within 8 inches of joint: NO - SEVERE AGG SPORATIC
130.8 ft. - Surface Spalling, from 12 to 04 o'clock, within 8 inches of joint: NO - PEELING CONCRETE
157.2 ft. - Surface Aggregate Visible, from 08 to 11 o'clock, within 8 inches of joint: NO - SEVERE AGG SPORATIC
233.7 ft. - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: NO - CIRCUM REBAR
240.7 ft. - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: NO - CIRCUM REBAR
254.4 ft. - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR
333.3 ft. - Surface Aggregate Visible, from 10 to 02 o'clock, within 8 inches of joint: YES - SEVERE AGG
343.6 ft. - Surface Reinforcement Visible, from 12 to 02 o'clock, within 8 inches of joint: NO - CIRCUM REBAR
| Distance | Code | Observation |
|---|---|---|
| 349.4 | SSS | BLISTERING PEELING CONCRETE |
| 157.2 | SAV | SEVERE AGG SPORATIC |
| 0 | MWM | — |
| 13.2 | SSS | PEELING CONCRETE |
| 81.5 | SAV | SEVERE AGG SPORATIC |
| 0 | MWL | — |
| 260.5 | SRV | CIRCUM REBAR |
| 0 | MGO | Conn. @ Mh, 3 O' Clock. Active |
| 343.6 | SRV | CIRCUM REBAR |
| 349.8 | AMH | 4:40AM |
| 0 | AMH | 4:05AM |
| 130.8 | SSS | PEELING CONCRETE |
| 2 | SSS | BLISTERING PEELING CONCRETE |
| 333.3 | SAV | SEVERE AGG |
| 349.4 | MGO | MAG COAT 90% FINISH |
| 240.7 | SRV | CIRCUM REBAR |
| 2 | MGO | MAG COAT 90% START |
| 233.7 | SRV | CIRCUM REBAR |
| 254.4 | SRV | CIRCUM REBAR |