05 1014A_05 1014_3122019_044750.mp4
2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE
2 ft. - General Observation - 95% MAG COAT START
70.8 ft. - Surface Spalling, from 02 to 04 o'clock, within 8 inches of joint: NO - FLAKING CONCRETE
97.2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - SLIGHTLY PEELING CONCRETE
203 ft. - Surface Spalling, from 01 to 04 o'clock, within 8 inches of joint: NO - PEELING CONCRETE
239.7 ft. - Surface Aggregate Visible, from 01 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG SPORATIC
257 ft. - Surface Spalling, from 08 to 11 o'clock, within 8 inches of joint: NO - FLAKING CONCRETE
| Distance | Code | Observation |
|---|---|---|
| 97.2 | SSS | SLIGHTLY PEELING CONCRETE |
| 0 | AMH | 4:35AM |
| 2 | SSS | BLISTERING PEELING CONCRETE |
| 0 | MGO | Conn. @ Mh, 3 O' Clock. Active |
| 0 | MWM | — |
| 2 | MGO | 95% MAG COAT START |
| 261.2 | SSS | BLISTERING PEELING CONCRETE |
| 203 | SSS | PEELING CONCRETE |
| 239.7 | SAV | SEVERE AGG SPORATIC |
| 70.8 | SSS | FLAKING CONCRETE |
| 0 | MWL | — |
| 261.7 | AMH | 5:00AM |
| 257 | SSS | FLAKING CONCRETE |
| 261.2 | MGO | 95% MAG COAT FINISH |