Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 15, 2019, 09:26 PM
  • Section#1_H 0343_H 0342__2152019__I0120.mp4

Date
02/15/2019
W/O
0754489
Weather
Dry
Operator/Surveyor
FRANKLIN
Sewer ID
Z00175
PipeID
P10793
Time
1:26 PM
Certificate
U-415-06024039
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
I0120
Sewer Name
H JOINT OUTFALL H - UNIT 4
City
PICO RIVERA
Loc. details
Parking Lot
Location Code
G
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
06
Purpose
Capital Improvement Program Assesment
Project
20190215DF_JOINT_OUTFALL_H_UNIT_4
Material
Reinforced Concrete Pipe
Shape
Circular
Height
21 in.
Upstream MH
H 0343
Downstream MH
H 0342
Dir. of Survey
Downstream
Length Surveyed
34.9 ft.
Total Length
34.9 ft.
Structural Index
3
Structural Quick
563A
Structural Rating
78
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
78
Pipe schematic from manhole H 0343 to H 0342
MH: H 0343MH: H 0342downstream0 ft. AMH - Upstream Manhole, Survey Begins - 1:30 PM0.1 ft. MWM - Water Mark, 25 %of cross sectional area0.1 ft. MWL - Water Level, 20 %of cross sectional area2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start10 ft. MGP - General Photograph17 ft. MGP - General Photograph22.4 ft. MGP - General Photograph22.4 ft. MGP - General Photograph29.4 ft. MGP - General Photograph29.4 ft. MGP - General Photograph33.3 ft. MGP - General Photograph33.3 ft. MGP - General Photograph34 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish34 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish34 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish34 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish34.9 ft. AMH - Downstream Manhole, Survey Ends - 2:06 PM

Observation photos (12)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Photograph

    10 ft. - General Photograph

  • General Photograph

    17 ft. - General Photograph

  • General Photograph

    22.4 ft. - General Photograph

  • General Photograph

    22.4 ft. - General Photograph

  • General Photograph

    29.4 ft. - General Photograph

  • General Photograph

    29.4 ft. - General Photograph

  • General Photograph

    33.3 ft. - General Photograph

  • General Photograph

    33.3 ft. - General Photograph

Observations (20)

DistanceCodeObservation
34SSS
0.1MWM
34SAP
29.4MGP
34SAV
22.4MGP
22.4MGP
2SSS
2SAP
0.1MWL
10MGP
29.4MGP
34SRV
33.3MGP
17MGP
33.3MGP
34.9AMH2:06 PM
2SRV
2SAV
0AMH1:30 PM

Properties (4)

customer
LACSD
datetime
2019-02-15T13:26:17-08:00
documentation
FRANKLIN, IGNACIO, SHADLER, RUVALCABA
is_lateral_inspection
false