Section#2_A 0379_A 0378__4172019__H0136.mp4
2 ft. - General Observation - MAG COAT 80% START
2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE
2 ft. - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG
24.8 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG
31 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - PEELING CONCRETE
36.4 ft. - General Observation - 50% MAG COAT START
57.3 ft. - Surface Aggregate Visible, from 10 to 02 o'clock, within 8 inches of joint: NO - SEVERE AGG
90.2 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: NO, Start - SEVERE AGG
318.6 ft. - Surface Aggregate Projecting, from 12 to 02 o'clock, within 8 inches of joint: NO - SEVERE AGG
| Distance | Code | Observation |
|---|---|---|
| 667 | SSS | BLISTERING PEELING CONCRETE |
| 0 | MWM | — |
| 31 | SSS | PEELING CONCRETE |
| 90.2 | SAP | SEVERE AGG |
| 667.8 | AMH | 5:35AM |
| 2 | MGO | MAG COAT 80% START |
| 36.4 | MGO | 50% MAG COAT START |
| 0 | AMH | 4:55AM |
| 2 | SSS | BLISTERING PEELING CONCRETE |
| 667 | SAP | SEVERE AGG |
| 57.3 | SAV | SEVERE AGG |
| 24.8 | SAV | SEVERE AGG |
| 318.6 | SAP | SEVERE AGG |
| 667 | MGO | 50% MAG COAT FINISH |
| 2 | SRV | SEVERE AGG |
| 667 | SRV | SEVERE AGG |
| 0 | MWL | — |