Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 2, 2019, 06:30 PM
  • 22 1145_22 1144_422019_115834.mp4

Date
04/02/2019
W/O
PENDING
Weather
Dry
Operator/Surveyor
SANTIAGO OBREGON
Sewer ID
Z00807
PipeID
P17524
Time
11:30 AM
Certificate
U-1014-06022541
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7953
Sewer Name
22 DUARTE TRUNK
City
DUARTE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
02
Purpose
Routine Assessment
Project
20190402SHO_DUARTE_TRUNK
Material
NRCP
Shape
Circular
Height
12 in.
Upstream MH
22 1145
Downstream MH
22 1144
Dir. of Survey
Downstream
Length Surveyed
352.8 ft.
Total Length
352.8 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole 22 1145 to 22 1144
MH: 22 1145MH: 22 1144downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - MH 11455.8 ft. SAV - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start98.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"143.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"192.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"247.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"298.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"347.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"352.8 ft. AMH - Downstream Manhole, Survey Ends - MH 1144352.8 ft. SAV - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish

Observation photos (1)

  • Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

    5.8 ft. - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

Observations (12)

DistanceCodeObservation
347.5TFC
0MWM
352.8AMHMH 1144
298.6TFC
247.3TFC
0MWL
5.8SAV
192.2TFC
0AMHMH 1145
98.7TFC
352.8SAV
143.5TFC

Properties (6)

custom_field_three
AGGREGATE THROUGHOUT
custom_field_two
3
customer
LACSD
datetime
2019-04-02T11:30:06-07:00
documentation
OBREGON, YOUNG, BRAR, CASTILLO
is_lateral_inspection
false