08 0010_08 0009_412019_041739.mp4
2 ft. - General Observation - 95% MAG COAT START
2 ft. - Surface Aggregate Missing, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG AREAS OF MISSING TILES
2 ft. - General Observation - 100% MISSING TILES START
6.8 ft. - Surface Reinforcement Corroded, from 12 to 02 o'clock, within 8 inches of joint: NO - LONG & CIRCUM REBAR
14.6 ft. - Deposits Settled Other, 40 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: NO - MISSING TILES UUNDER FLOW
22.6 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - LONG & CIRCUM CORRODED & MISSING
33.4 ft. - General Observation - MISSING TILES 5% START
48.8 ft. - General Observation - 100% MISSING TILES 1 SECTION
106.8 ft. - General Observation - 60% MAG COAT
184.5 ft. - General Observation - 20% MISSING TILES START
228.9 ft. - General Observation - 90% MAG COAT
269.3 ft. - Surface Reinforcement Corroded, from 12 to 02 o'clock, within 8 inches of joint: NO - CIRCUM REBAR
| Distance | Code | Observation |
|---|---|---|
| 0 | MWL | — |
| 0 | MWM | — |
| 228.9 | MGO | 90% MAG COAT |
| 2 | MGO | 95% MAG COAT START |
| 337.8 | AMH | 4:25AM |
| 14.6 | DSZ | MISSING TILES UUNDER FLOW |
| 213.3 | MWM | — |
| 269.3 | SRC | CIRCUM REBAR |
| 2 | SAM | SEVERE AGG AREAS OF MISSING TILES |
| 337.2 | MGO | 90 5 MAG COAT FINISH |
| 0 | AMH | 4:00AM |
| 106.8 | MWM | — |
| 6.8 | SRC | LONG & CIRCUM REBAR |
| 106.8 | MGO | 60% MAG COAT |
| 48.8 | MGO | 100% MISSING TILES 1 SECTION |
| 337.2 | MGO | 20% MISSINGTILES FINISH |
| 22.6 | SRC | LONG & CIRCUM CORRODED & MISSING |
| 33.4 | MGO | MISSING TILES 5% START |
| 64.7 | ID | — |
| 2 | MGO | 100% MISSING TILES START |
| 337.2 | SAM | SEVERE AGG AREAS OF MISSING TILES |
| 184.5 | MGO | 20% MISSING TILES START |