Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 26, 2019, 07:50 AM
  • A 1038_A 1037_3262019_012101.mp4

  • A 0138_A 1037_3262019_012023.mp4

Date
03/26/2019
W/O
0762538
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00918
PipeID
P20813
Time
12:50 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1160
Sewer Name
A JOA-1A DISTRICT 5 INTERCEPTOR RELIEF
City
GARDENA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
20
Purpose
Routine Assessment
Project
20190326MDM_JOA_1A_DISTRICT_5_INTERCEPTOR_RELIEF
Material
RCP-PTL
Shape
Circular
Height
54 in.
Upstream MH
A 1038
Downstream MH
A 1037
Dir. of Survey
Downstream
Length Surveyed
97 ft.
Total Length
97 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole A 1038 to A 1037
MH: A 1038MH: A 1037downstream0 ft. AMH - Upstream Manhole, Survey Begins - 1:15AM0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area8 ft. MGO - General Observation - 54"RCP-PTL97 ft. AMH - Downstream Manhole, Survey Ends - 1:25AM

Observation photos (1)

  • General Observation - 54"RCP-PTL

    8 ft. - General Observation - 54"RCP-PTL

Observations (5)

DistanceCodeObservation
0AMH1:15AM
0MWL
8MGO54"RCP-PTL
0MWM
97AMH1:25AM

Properties (6)

custom_field_three
LINER GOOD COND
custom_field_two
4
customer
LACSD
datetime
2019-03-26T00:50:23-07:00
documentation
MARTIN,REVELES,OLIVER 111,CASTILLO
is_lateral_inspection
false