Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 19, 2019, 07:20 AM
  • 05 1423_05 2409_4192019_004014.mp4

Date
04/19/2019
W/O
0766293
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00513
PipeID
P06643
Time
12:20 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1182
Sewer Name
05 REDONDO BEACH BOULEVARD EXTENSION TRUNK
City
GARDENA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
18
Purpose
Capital Improvement Program Assesment
Project
20190419MDM_REDONDO_BEACH_BOULEVARD_EXTENSION_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
05 1423
Downstream MH
05 2409
Dir. of Survey
Downstream
Length Surveyed
207 ft.
Total Length
207 ft.
Structural Index
2
Structural Quick
392A
Structural Rating
51
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
53
Pipe schematic from manhole 05 1423 to 05 2409
MH: 05 1423MH: 05 2409downstream-0.1 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - HAIRLINE0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 12:45AM0 ft. MWM - Water Mark, 20 %of cross sectional area13.7 ft. FC - Fracture Circumferential, from 09 to 01 o'clock, within 8 inches of joint: YES - H16.4 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - H19.9 ft. FC - Fracture Circumferential, from 08 to 09 o'clock, within 8 inches of joint: YES - H22.6 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - H25.6 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - H25.6 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - H26.3 ft. FL - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES, Start - H28.4 ft. FC - Fracture Circumferential, from 09 to 01 o'clock, within 8 inches of joint: YES - H31.6 ft. FC - Fracture Circumferential, from 03 to 04 o'clock, within 8 inches of joint: YES - H33 ft. FL - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES, Finish - H35.4 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - H37.7 ft. FL - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES, Start - HAIRLINE AT JOINTS37.7 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - HAIRLINES AT JOINTS52.8 ft. FL - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES, Start - SL59.8 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES, Start - H76.9 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Open82.8 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES, Finish - H82.8 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES, Start - SLIGHT94.1 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES, Start - SLIGHT94.1 ft. FL - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES, Finish - SLIGHT97.3 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - SL143.1 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Open157.1 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES, Start - H160.5 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES, Finish - H196.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES - THROUGHOUT REACH196.1 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - FLAKING205 ft. FC - Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES - SL206.7 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES, Finish - SLIGHT206.7 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active206.7 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active206.7 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - FLAKING206.7 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES, Finish - SLIGHT206.7 ft. FL - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES, Finish - 25% HAIRLINE AT JOINTS206.7 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - 80% HAIRLINE AT JOINTS206.9 ft. AMH - Downstream Manhole, Survey Ends - 1:30AM

Observation photos (7)

  • Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES, Start - H

    26.3 ft. - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES, Start - H

  • Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES, Start - SL

    52.8 ft. - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES, Start - SL

  • Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES, Start - H

    59.8 ft. - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES, Start - H

  • Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES, Start - SLIGHT

    82.8 ft. - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES, Start - SLIGHT

  • Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES, Start - SLIGHT

    94.1 ft. - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES, Start - SLIGHT

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES - THROUGHOUT REACH

    196.1 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES - THROUGHOUT REACH

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - FLAKING

    196.1 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - FLAKING

Observations (39)

DistanceCodeObservation
26.3FLH
28.4FCH
206.7FLSLIGHT
206.9AMH1:30AM
25.6FCH
205FCSL
94.1FLSLIGHT
37.7FLHAIRLINE AT JOINTS
196.1DAGSTHROUGHOUT REACH
59.8FLH
206.7MGOConn. @ Mh, 9 O' Clock. Active
157.1FLH
25.6FCH
97.3FCSL
82.8FLH
206.7MGOConn. @ Mh, 3 O' Clock. Active
52.8FLSL
13.7FCH
76.9TFOpen
33FLH
206.7SSSFLAKING
0MWL
82.8FLSLIGHT
94.1FLSLIGHT
143.1TFOpen
0AMH12:45AM
37.7FCHAIRLINES AT JOINTS
31.6FCH
206.7FLSLIGHT
22.6FLH
206.7FL25% HAIRLINE AT JOINTS
-0.1FCHAIRLINE
206.7FC80% HAIRLINE AT JOINTS
0MWM
196.1SSSFLAKING
160.5FLH
35.4FLH
19.9FCH
16.4FCH

Properties (6)

custom_field_three
SLIGHT FRACTURE JOINT TO JOINT LONGER
custom_field_two
2
customer
LACSD
datetime
2019-04-19T00:20:24-07:00
documentation
MARTIN,REVELES,OLIVER 111,RUVALCABA
is_lateral_inspection
false