Wastewater/Activity/PacpInspection/1.0Apr 8, 2019, 07:22 AM
  • 08 0505_08 0504_482019_004205.mp4

Date
04/08/2019
W/O
0765023
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00021
PipeID
P00564
Time
12:22 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1177
Sewer Name
08 VICTORIA STREET TRUNK
City
GARDENA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
04
Purpose
Capital Improvement Program Assesment
Project
20190408MDM_VICTORIA_STREET_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
08 0505
Downstream MH
08 0504
Dir. of Survey
Downstream
Length Surveyed
152.8 ft.
Total Length
152.8 ft.
Structural Index
2
Structural Quick
4133
Structural Rating
41
O&M Index
3
O&M Quick
3100
O&M Rating
3
Overall Index
2
Overall Quick
Overall Rating
44
Pipe schematic from manhole 08 0505 to 08 0504
MH: 08 0505MH: 08 0504downstream0 ft. AMH - Upstream Manhole, Survey Begins - 12:35AM0 ft. MWM - Water Mark, 10 %of cross sectional area0 ft. MWL - Water Level, 0 %of cross sectional area - NO FLOW2 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - PEELING FLAKING SURFACE9.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped11.6 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - HAIRLINE11.6 ft. FC - Fracture Circumferential, from 01 to 03 o'clock, within 8 inches of joint: YES - SLIGHT12.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped16.5 ft. RMJ - Roots Medium Joint, from 04 to 08 o'clock, 25 %, within 8 inches of joint: YESR24.7 ft. FC - Fracture Circumferential, from 12 to 02 o'clock, within 8 inches of joint: YES - SL24.7 ft. FC - Fracture Circumferential, from 10 to 12 o'clock, within 8 inches of joint: YES - SL29.3 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - PEELING FLAKING SURFACE34.9 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H34.9 ft. FC - Fracture Circumferential, from 07 to 11 o'clock, within 8 inches of joint: YES - SL80.4 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - H90.7 ft. FC - Fracture Circumferential, from 07 to 08 o'clock, within 8 inches of joint: YES - H95.5 ft. FC - Fracture Circumferential, from 02 to 05 o'clock, within 8 inches of joint: YES - SL98.9 ft. MLC - Lining Change, Other (enter details in Field 39) - PIPE IS LINED98.9 ft. MGO - General Observation - PIPE LINING102.8 ft. MGO - General Observation - TORN LINER 12:00 START108.2 ft. MGO - General Observation - TORN LINER 12:00 FINISH108.2 ft. MLC - Lining Change, Other (enter details in Field 39) - LINER ON PIPE FINISH110 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped111.8 ft. FC - Fracture Circumferential, from 01 to 04 o'clock, within 8 inches of joint: YES - SLIGHT116.6 ft. FC - Fracture Circumferential, from 01 to 05 o'clock, within 8 inches of joint: YES - H116.6 ft. FC - Fracture Circumferential, from 07 to 08 o'clock, within 8 inches of joint: YES - H117.5 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - H121.6 ft. FM - Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Start - SLIGHT121.7 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish - H122.6 ft. MGP - General Photograph - MULTIPLE SLIGHT FRACTURES127.7 ft. FM - Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish - SLIGHT131.7 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - H131.7 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - SL141.7 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - H152.4 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Capped152.4 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Capped152.8 ft. AMH - Downstream Manhole, Survey Ends - 1:20AM

Observation photos (8)

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - PEELING FLAKING SURFACE

    2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - PEELING FLAKING SURFACE

  • Roots Medium Joint, from 04 to 08 o'clock, 25 %, within 8 inches of joint: YESR

    16.5 ft. - Roots Medium Joint, from 04 to 08 o'clock, 25 %, within 8 inches of joint: YESR

  • Lining Change, Other (enter details in Field 39) - PIPE IS LINED

    98.9 ft. - Lining Change, Other (enter details in Field 39) - PIPE IS LINED

  • General Observation - PIPE LINING

    98.9 ft. - General Observation - PIPE LINING

  • General Observation - TORN LINER 12:00 START

    102.8 ft. - General Observation - TORN LINER 12:00 START

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - H

    117.5 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - H

  • Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Start - SLIGHT

    121.6 ft. - Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Start - SLIGHT

  • General Photograph - MULTIPLE SLIGHT FRACTURES

    122.6 ft. - General Photograph - MULTIPLE SLIGHT FRACTURES

Observations (37)

DistanceCodeObservation
98.9MLCPIPE IS LINED
34.9FLH
122.6MGPMULTIPLE SLIGHT FRACTURES
29.3SSSPEELING FLAKING SURFACE
16.5RMJ
0AMH12:35AM
117.5FLH
0MWM
95.5FCSL
90.7FCH
80.4FCH
131.7FCH
24.7FCSL
24.7FCSL
108.2MGOTORN LINER 12:00 FINISH
11.6FLHAIRLINE
116.6FCH
102.8MGOTORN LINER 12:00 START
121.6FMSLIGHT
152.4MGOConn. @ Mh, 3 O' Clock. Capped
111.8FCSLIGHT
2SSSPEELING FLAKING SURFACE
9.4TFCCapped
12.4TFCCapped
152.4MGOConn. @ Mh, 9 O' Clock. Capped
131.7FCSL
127.7FMSLIGHT
11.6FCSLIGHT
108.2MLCLINER ON PIPE FINISH
98.9MGOPIPE LINING
110TFCCapped
152.8AMH1:20AM
0MWLNO FLOW
116.6FCH
141.7FCH
34.9FCSL
121.7FLH

Properties (6)

custom_field_three
MULTIPLE SLIGHT FRACTURES JOINT TO JOINT
custom_field_two
2
customer
LACSD
datetime
2019-04-08T00:22:27-07:00
documentation
MARTIN,REVELES,OLIVER 111,RUVALCABA
is_lateral_inspection
false