Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 4, 2019, 07:04 AM
  • 32 1236_32 1235 _04042019_002126.mp4

Date
04/04/2019
W/O
756114
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00832
PipeID
P19705
Time
12:04 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6446
Sewer Name
32 BOUQUET CANYON TRUNK
City
SANTA CLARITA
Loc. details
Main Highway - Suburban/Rural
Location Code
B
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
09
Purpose
Routine Assessment
Project
WO_756114_TV32007_MAR2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
32 1236
Downstream MH
32 1235
Dir. of Survey
Downstream
Length Surveyed
402.5 ft.
Total Length
402.5 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
2O00
O&M Rating
160
Overall Index
2
Overall Quick
Overall Rating
163
Pipe schematic from manhole 32 1236 to 32 1235
MH: 32 1236MH: 32 1235downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 32 12360 ft. MWM - Water Mark, 10 %of cross sectional area0 ft. MGO - General Observation - RUN LIST STATED NRCP BUT ACTUAL MATERIAL IS VCP. SECTION INFO CHANGED TO REFLECT ACTUAL PIPE MATERIAL.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start392.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES400.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish402.5 ft. AMH - Downstream Manhole, Survey Ends - 32 1235

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    392.5 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (8)

DistanceCodeObservation
2DAGS
402.5AMH32 1235
400.6DAGS
0MWL
0AMH32 1236
0MWM
0MGORUN LIST STATED NRCP BUT ACTUAL MATERIAL IS VCP. SECTION INFO CHANGED TO REFLECT ACTUAL PIPE MATERIAL.
392.5CM

Properties (6)

additional_info
SC366214
custom_field_two
3
customer
LACSD
datetime
2019-04-04T00:04:24-07:00
documentation
PRO PIPE
is_lateral_inspection
false