Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 15, 2019, 09:28 AM
  • 05 1094_05 1093_03152019_031545.mp4

Date
03/15/2019
W/O
755956
Weather
Dry
Operator/Surveyor
E.RUIZ
Sewer ID
Z00488
PipeID
P06328
Time
2:28 AM
Certificate
U-715-07000753
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6477
Sewer Name
05 MONETA EXTENSION TRUNK, SECTION 1
City
GARDENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
18
Purpose
Routine Assessment
Project
RFIR_WO_755956_TV05328_MAR2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
05 1094
Downstream MH
05 1093
Dir. of Survey
Downstream
Length Surveyed
321.9 ft.
Total Length
321.9 ft.
Structural Index
3
Structural Quick
5146
Structural Rating
53
O&M Index
3
O&M Quick
4122
O&M Rating
8
Overall Index
3
Overall Quick
Overall Rating
61
Pipe schematic from manhole 05 1094 to 05 1093
MH: 05 1094MH: 05 1093downstream0 ft. MWL - Water Level, 35 %of cross sectional area0 ft. MWM - Water Mark, 55 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 10944.9 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES16.9 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES23.2 ft. TFA - Tap Factory Made Active, at 01 o'clock, -, within 8 inches of joint: YES, 8"25.2 ft. FM - Fracture Multiple, from 08 to 11 o'clock, within 8 inches of joint: YES40.6 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES50.4 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES56.5 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES65.9 ft. FM - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES78.2 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES84.3 ft. FM - Fracture Multiple, from 09 to 01 o'clock, within 8 inches of joint: YES90.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start102.3 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES108.4 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES111.8 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES117.9 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES124.6 ft. TFA - Tap Factory Made Active, at 01 o'clock, -, within 8 inches of joint: YES, 8"129.3 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start197.5 ft. MWLS - Water Level, Sag in pipe, 10 %of cross sectional area, Start215.5 ft. B - Broken, from 10 to 03 o'clock, within 8 inches of joint: YES225.8 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: YES, 8"291.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 03 o'clock, , within 8 inches of joint: YES, Change319.1 ft. MWLS - Water Level, Sag in pipe, 10 %of cross sectional area, Finish319.1 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish319.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 03 o'clock, , within 8 inches of joint: YES, Finish321.9 ft. AMH - Downstream Manhole, Survey Ends - 05 1093

Observation photos (15)

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    4.9 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

    16.9 ft. - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 11 o'clock, within 8 inches of joint: YES

    25.2 ft. - Fracture Multiple, from 08 to 11 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    40.6 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    50.4 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    56.5 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    65.9 ft. - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 01 o'clock, within 8 inches of joint: YES

    84.3 ft. - Fracture Multiple, from 09 to 01 o'clock, within 8 inches of joint: YES

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    90.4 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    102.3 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    108.4 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    111.8 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    117.9 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    129.3 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Broken, from 10 to 03 o'clock, within 8 inches of joint: YES

    215.5 ft. - Broken, from 10 to 03 o'clock, within 8 inches of joint: YES

Observations (28)

DistanceCodeObservation
65.9FM
25.2FM
319.1MWLS
0MWL
129.3FM
56.5CM
0MWM
319.1FM
111.8FM
321.9AMH05 1093
117.9CM
291.4DAGS
50.4FM
16.9CL
90.4DAGS
108.4CM
40.6CM
78.2CL
124.6TFA
215.5B
23.2TFA
4.9CM
225.8TFA
102.3CM
84.3FM
319.2DAGS
197.5MWLS
0AMH05 1094

Properties (5)

custom_field_two
2
customer
LACSD
datetime
2019-03-15T02:28:49-07:00
documentation
PROPIPE
is_lateral_inspection
false